7
Product Specification
7-2
Optional accessories
Optional Accesories
Interlock adapter for VRV
Notes:
1. Installation box market with ** is required for each adapter marked *.
2. Up to 2 adapters can be fixed for each installation box.
3. Only one installation box can be installed for each indoor unit.
4. Up to 2 adapters can be fixed for each indoor unit.
5. Flexible duct size *** is for the duct from HRV unit to branch duct (or air outlet)
Model
Item
VAM150FA
VAM250FA
VAM350FA
VAM500FA
VAM650FA
Controlling
device
Remote control
BRC301B61
Wired remote controller
BRC1D52
Centralized
controlling
device
Central remote control
DCS302C51 (for general) DCS302C51 (For EC market)
Unified On/Off control
DCS301B61 (for general) DCS301B51 (For EC market)
schedule timer
DST301B51 (for general) DST301B51 (For EC market)
PC board
adapter
KRP2A61 (for general) KRP2A51 (for EC market)
KRP50-2
KRP50-2A90 (Mounted electric component assy of HRV)
BRP4A50
Additional
function
Silencer
Model name
-
-
-
KDDM24A50
Ø
200
KDDM24A100
Ø
200
Nominal pipe diameter (mm)
-
-
-
Air filter for replacement
YAFF323F15
YAFF323F25
YAFF323F35
YAFF323F50
YAFF323F65
High efficiency filter
YAFF323F15
YAFF323F25
YAFF323F35
YAFF323F150
YAFF323F65
Duct adapter
-
-
-
-
-
Nominal pipe diameter (mm)
-
-
-
-
-
Duct adapter
-
-
-
VKM50G
VKM80G
Adapter for discharge
-
-
-
KDAJ25K36
KDA25K56
Model
Item
VAM800FA
VAM100FA
VAM1500FA
VAM2000FA
Controlling
device
Remote control
BRC301B61
Wired remote controller
BRC1D52
Centralized
controlling
device
Central remote control
DCS302C51 (for general) DCS302C51 (For EC market)
Unified On/Off control
DCS301B61 (for general) DCS301B51 (For EC market)
schedule timer
DST301B51 (for general) DST301B51 (For EC market)
PC board
adapter
Wiring adapter for
electrical appandices
KRP2A61 (for general) KRP2A51 (For EC market)
For humidifier
KRP50-2
Installation box for
adapte PCB
KRP50-2A90 (Mounted electric component assy of HRV)
For heater kit
BRP4A50
Additional
function
Silencer
Model name
KDDM24A100
Ø
250
KDDM24A100
Ø
250
KDDM24A100x2
Ø
250
KDDM24A100x2
Ø
250
Nominal pipe diameter (mm)
Air filter for replacement
YAFF323F65
YAFF323F100
YAFF323F65x2
YAFF323F100x2
High efficiency filter
YAFF323F65
YAFF323F100
YAFF323F165x2
YAFF323F100x2
Duct adapter
-
-
YDFA25A1
Ø
250
YDFA25A1
Ø
250
Nominal pipe diameter (mm)
Duct adapter
VKM80G
KKM100G
-
-
Adapter for discharge
KDAJ25K56
KDAJ25K56
-
-
Indoor unit
FXYC-K
FXYK-K
FXYF-K
FXYS-K
FXYH-K
FXYA-K
FXYL(M)-KJ
FXYM-K(J)
Adapter for wiring
KRP1B61 *
KRP1B61
KRP1B2 *
KRP1B61
KRP1B3
KRP1B61
Installation box for adapter PCB **
KRP1B96
Note 2,3
-
KRP1C98
Note 4
-
-
KRP1B93
Note 3
-
-
3TW24921-1A
Содержание VAM-FA8VE
Страница 1: ...EEDEN07 201 technical data heat reclaim ventilation VAM FA8VE VKM GAMV1 VKM GAV1 ...
Страница 2: ......
Страница 152: ......
Страница 272: ...2 11 270 HRV VKM GA M V1 HRV Heat Reclaim Ventilation Length Flow rate ...
Страница 275: ...2 11 HRV VKM GA M V1 HRV Heat Reclaim Ventilation 273 Temperature conversion table ...
Страница 279: ...2 11 HRV VKM GA M V1 HRV Heat Reclaim Ventilation 277 R 410A Saturation pressure gauge pressure chart ...
Страница 281: ...2 11 HRV VKM GA M V1 HRV Heat Reclaim Ventilation 279 Pressure enthalpy curves of HFC32 125 50 50 wt Z0169 R 410A ...