The following parameters are important on Daikin applications . A summary is shown in
Table 63: Parameter Settings on page 89
.
All other should not be adjusted. Parameter data is specific to MD5 firmware version 2.13.
Group 99: Start-Up Data
This group defines special Start-up data required to:
• Set up the drive .
• Enter motor information
NOTE:
Parameters checked under the heading “S” can be
modified only when the drive is stopped.
Table 4: Group 99: Start-up Data
Code Description
Range
Resolution
Default
S
9901
LANGUAGE
0…16
1
0
(ENGLISH)
Selects the display language .
0 = ENGLISH
1 = ENGLISH (AM) 2 = DEUTSCH
3 = ITALIANO 4 = ESPAÑOL
5 = PORTUGUES
6 = NEDERLANDS 7 = FRANCAIS
8 = DANSK
9 = SUOMI
10 = SVENSKA 11 = RUSSKI
12 = POLSKI
13 = TÜRKCE
14 = CZECH
15 = MAGYAR 16 = RESERVED
9902
APPLIC MACRO
-3…15, 31
1
1(HVAC
DEFAULT)
Selects an application macro. Application macros automatically edit parameters to configure the MD5 for a particular application. See Application macros for
application macro descriptions .
1= HVAC DEFAULT
2= SUPPLY FAN
3= RETURN FAN
4= COOLING TOWER FAN
5= CONDENSER
6= BOOSTER PUMP
7= PUMP ALTERNATION
8= INTERNAL TIMER 9= INTERNAL TIMER WITH CONSTANT SPEEDS
10= FLOATING POINT 11= DUAL SETPOINT PID 12= DUAL SETPOINT PID WITH CONSTANT SPEEDS
13= E-BYPASS
14= HAND CONTROL
15= E-CLIPSE
31 = LOAD FD SET - FrontDrop parameter values as defined by the FlashDrop file. Parameter view is selected by parameter 1611 PARAMETER VIEW.
• FlashDrop is an optional device for fast copying of parameters to unpowered drives . FlashDrop allows easy customization of the parameter list, e .g .
selected parameters can be hidden . For more information, see MFDT-01 FlashDrop User’s Manual [3AFE68591074 (English)] .
-1 = USER S1 SAVE, -3 = USER S2 SAVE - With these it is possible to save two different user parameter sets into the drive permanent memory for later use .
Each set contains parameter settings, including Group 99: START-UP DATA, and the results of the motor identification run.
0 = USER S1 LOAD, -2 = USER S2 LOAD - With these the user parameter sets can be taken back in use .
9905
MOTOR NOM VOLT
115…345 V
(200 V, US)
230…690 V
(400 V, US)
288…862 V
(600 V, US)
1 V
1 V
1 V
230 V (US)
460 V (US)
575 V (US)
Defines the nominal motor voltage.
• Must equal the value on the motor rating plate .
• The MD5 cannot supply the motor with a voltage greater than the input power (mains) voltage .
9906
MOTOR NOM CURR
0 .15 ·
I
2
n
…
1 .5 ·
I
2
n
0 .1 A
1 .0 ·
I
2
n
Defines the nominal motor current.
• Must equal the value on the motor rating plate .
• Range allowed: 0 .15…1 .5 ·
I
2
n
(where
I
2
n
is drive current) .
9907
MOTOR NOM FREQ
10 .0…500 .0
Hz
0 .1 Hz
60 .0 Hz
(US)
Defines the nominal motor frequency.
• Range: 10…500 Hz (typically 50 or 60 Hz)
• Sets the frequency at which output voltage equals the MOTOR NOM VOLT .
• Field weakening point = Nom Freq · Supply Volt / Mot Nom Volt
9908
MOTOR NOM SPEED
50…30000
rpm
1 rpm
Size
dependent
Defines the nominal motor speed.
• Must equal the value on the motor rating plate .
9909
MOTOR NOM POWER
0 .15…
1 .5 · P
n
0 .1 hp
1 .0 · P
n
Defines the nominal motor power.
• Must equal the value on the motor rating plate .
OM 1191 • MD5 VFD 12 www .DaikinApplied .com