54
ENG
pRack PR300T +0300018EN rel. 1.5 - 02.05.2017
Mask index
Display description
Description
Def
.
U
.
of M
.
V
alues
A. Unit status
Aa01 (display
only)
Pressure
Suction pressure (line 1)
---
…
…(**)
Sat.Temp.
Suction saturated temperature (line 1)
---
…
…(**)
ActualSet
Actual setpoint for pressure regulation (with compensations applied, line 1)
---
…
…(**)
Diff eren.
Regulation diff erential for pressure regulation (line 1)
---
…
…(**)
Aa02 (display
only)
Pressure
Suction pressure (line 1)
---
…
…(**)
Sat.Temp.
Suction saturated temperature (line 1)
---
…
…(**)
ActualSet
Actual setpoint for temperature regulation (with compensations applied, line 1)
---
…
…(**)
Diff eren.
Regulation diff erential for temperature regulation (line 1)
---
…
…(**)
Aa03 (display
only)
Act/Req.
Power delivered/Power requested per suction line (line 1)
---
%
0 | 0 …100 | 100
Reg. Status
Regulation status (according to the type of regulation set, line 1)
---
---
Stop | Increase
Decrease
Stand-by
Functioning
Timings | Alarms
Reg. Type
Compressor regulation type (line 1)
---
---
Proportional Band
Dead Zone
Setpoint
Actual suction setpoint (with compensations applied, line 1)
---
…
…(**)
Aa04 (display
only)
C01, C02, …C12
Time remaining for next compressor startup (line 1)
---
s
0…32000
C01
Power delivered from compressor 1 of line 1 (a "!" to the right of the value means that some
form of compressor power forcing is active, e.g., safety times, alarms, startup procedure)
---
%
0…100
…
…
…
…
…
C12
Power delivered from compressor 12 (line 1)
---
%
0…100
Aa05 (display
only)
Temperature
Suction temperature (line 1)
---
…
…(**)
Superheat.
Superheating (line 1)
---
…
…(**)
Aa11 (display
only)
Disch. 1
Discharge temperature compressor 1 (line 1)
---
…
…(**)
…
…
…
…
…
Disch. 6
Discharge temperature compressor 6 (line 1)
---
…
…(**)
Aa12 (display
only)
Oil Temp 1
Oil temperature compressor 1 (line 1)
---
…
…(**)
…
…
…
…
…
Oil Temp 6
Oil temperature compressor 6 (line 1)
---
…
…(**)
Aa13 (display
only)
In.liq.1: DO
Digital output number associated and liquid injection/economizer (*) status compressor 1
(line 1)
---
… 0…29
…
…
…
…
…
In.liq.6: DO
Digital output number associated and liquid injection/economizer (*) status compressor 6
(line 1)
---
… 0…29
Aa15 (display
only)
Discharge temperature
Discharge temperature Digital Scroll
TM
compressor (line 1)
---
…
…(**)
Cap.Reduction
Capacity reduction Digital Scroll
TM
compressor (line 1) in progress
NO | YES
Oil sump T.
Oil sump temperature Digital Scroll
TM
compressor (line 1) ---
…
…(**)
Oil status
Oil dilution status Digital Scroll
TM
compressor (line 1)
OK | Diluted
Aa16 (display
only)
Status
Operational status Digital Scroll
TM
compressor (line 1)
---
---
OFF | Start
ON | Alarm
Count
Safety time count Digital Scroll
TM
compressor (line 1) ---
s
0…999
Compr.
Status Digital Scroll
TM
compressor (line 1)
---
---
ON | OFF
Valve
Status Digital Scroll
TM
valve (line 1)
---
---
ON | OFF
Cap.Req.
Capacity requested Digital Scroll
TM
compressor (line 1)
---
%
0…100
ActualCapac.
Actual capacity Digital Scroll
TM
compressor (line 1)
---
%
0…100
Aa20 (display
only)
Pressure
Condensing pressure (line 1)
---
…
…(**)
Sat.Temp.
Condensing saturated temperature (line 1)
---
…
…(**)
ActualSet
Actual setpoint for pressure regulation (with compensations applied, line 1)
---
…
…(**)
Diff eren
Regulation diff erential for pressure regulation (line 1)
---
…
…(**)
Aa21 (display
only)
Pressure
Condensing pressure (line 1)
---
…
…(**)
Sat.Temp.
Condensing saturated temperature (line 1)
---
…
…(**)
ActualSet
Actual setpoint for temperature regulation (with compensations applied, line 1)
---
…
…(**)
Diff eren.
Regulation diff erential for temperature regulation (line 1)
---
…
…(**)
Aa22 (display
only)
Act/Req
Power delivered/Power requested per condensing line (line 1)
---
%
0 | 0 …100 | 100
Reg. Status
Regulation status (according to the type of regulation set, line 1)
---
---
Stop | Increase
Decrease
Stand-by
Functioning
Timings | Alarms
Reg. Type
Gas cooler regulation type (line 1)
---
---
Proportional Band
Dead Zone
Setpoint
Actual setpoint gas cooler (line 1)
---
…
…(**)
Aa23 (display
only)
F1
Power delivered from fan 1 of line 1 (a "!" to the right of the value means that some form of
power forcing is active)
---
%
0…100
…
…
…
…
…
F8
Power delivered from fan 8 of line 1 (a "!" to the right of the value means that some form of
power forcing is active)
---
%
0…100
Aa24 (display
only)
F9
Power delivered from fan 9 of line 1 (a "!" to the right of the value means that some form of
power forcing is active)
---
%
0…100
…
…
…
…
…
F16
Power delivered from fan 16 of line 1 (a "!" to the right of the value means that some form of
power forcing is active)
---
%
0…100
Aa25 (display
only)
Discharge temperature
Discharge temperature (line 1)
---
…
…(**)
External temperature
External temperature (line 1)
---
…
…(**)
Aa31 (display
only)
Pressure
Suction pressure (line 2)
---
…
…(**)
Sat.Temp.
Suction saturated temperature (line 2)
---
…
…(**)
ActualSet
Actual setpoint for pressure regulation (with compensations applied, line 2)
---
…
…(**)
Diff eren.
Regulation diff erential for pressure regulation (line 2)
---
…
…(**)
Aa32 (display
only)
Pressure
Suction pressure (line 2)
---
…
…(**)
Sat.Temp.
Suction saturated temperature (line 2)
---
…
…(**)
ActualSet
Actual setpoint for temperature regulation (with compensations applied, line 2)
---
…
…(**)
Diff eren.
Regulation diff erential for temperature regulation (line 2)
---
…
…(**)
Aa33 (display
only)
Act/Req.
Power delivered/Power requested per suction line (line 2)
---
%
0 | 0 …100 | 100
Reg. Status
Regulation status (according to the type of regulation set, line 2)
---
---
Stop | Increase
Decrease
Stand-by
Functioning
Timings | Alarms
Reg. Type
Compressor regulation type (line 2)
---
---
Proportional Band
Dead Zone
Setpoint
Actual suction setpoint (with compensations applied, line 2)
---
…
…(**)
Page 103 of 172
Copyright HPL March 2021
P4114S Rev 03
Содержание Hubbard GCU2040PXB1
Страница 4: ...Page 4 of 172 Copyright HPL March 2021 P4114S Rev 03...
Страница 44: ...4 Wiring Schematics Model GCU2040PXB1 Part Number D4155S Page 44 of 172 Copyright HPL March 2021 P4114S Rev 03...
Страница 49: ...6 Carel PR300T CO2 Controller manual Page 49 of 172 Copyright HPL March 2021 P4114S Rev 03...
Страница 144: ...Page 144 of 172 Copyright HPL March 2021 P4114S Rev 03...
Страница 161: ...8 PRESSURE ENTHALPY DIAGRAM FOR R744 REFRIGERANT Page 161 of 172 Copyright HPL March 2021 P4114S Rev 03...
Страница 165: ...9 Commissioning Form Page 165 of 172 Copyright HPL March 2021 P4114S Rev 03...