2.5 Expansion
card
From version 3.3.0, an I/O expansion card can be used to provide additional
analogue and digital channels, ideal when there is a high number of
compressors and corresponding alarms, or with complex heat recovery
systems that require of numerous temperature sensors in the water and
CO2 circuits (see technical leafl et +0500059IE for the product’s electrical
and physical specifi cations). The universal inputs/outputs (marked U on
the connection diagram) can be confi gured by pRack pR300T to connect
active and passive probes, digital inputs, analogue and PWM outputs, up
to a total of 10. A further 6 digital outputs are also available.
1
2
3
4
5
6
7
8
9
1
0
11
1
2
1
3
1
4
1
5
with
o
ff
set
no
o
ff
set
1
9.2
K
9.6
K
38.4
K
57.6
K
CAREL
Modbus
ON
OFF
A
ddress
Ext
.
Prot
Baud
A
ddress
Ext Baud Prot
8
5
6
7
1
2
4
3
Fig. 2.a
Key:
1
Power connector [G(+), G0(-), Vbat]
2
Universal inputs/outputs
3
+Vdc power supply for active probes
4
+5V power supply for ratiometric probes
5
Relay digital outputs
6
BMS connector
7
Communication indicator LED
8
Confi guration indicator LED
Confi guration dipswitches
For correct communication with pRack pR300T, the dipswitches on the
expansion card should be confi gured as follows:
•
Address: 15
•
Ext: no off set
•
Baud: 19.2 K
•
Prot: CAREL
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
with offset
no offset
19.2 K
9.6 K
38.4 K
57.6 K
CAREL
Modbus
ON
OFF
Address
Ext.
Prot
Baud
Fig. 2.k
The pRack pR300T software (version 3.3.0 and higher) off ers the possibility
to extend the number of I/Os by expansion card directly from the Wizard,
in screen Ib1f:
Wizard
Ib1f
Enable I/O expansion
board management:
NO
Additional confi guration of the expansion card is possible on Fda01,
under PROGRAMMING
Æ
F.Settings
Æ
d.FIELDBUS:
L1-Fieldbus
Fda01
Enable cpCOe: NO
Offline pattern: DIS
Digital output pattern
1:OFF 2:OFF 3:OFF
4:OFF 5:OFF 6:OFF
When enabling “Offl
ine pattern”, the status of the outputs can be
confi gured if the card is offl
ine from the pRack.
Both the digital (Fda01) that analogue outputs (Fda02) can be confi gured
Univers.input pattern
UI01:--0% UI02:--0%
UI03:--0% UI04:--0%
UI05:--0% UI06:--0%
UI07:--0% UI08:--0%
UI09:--0% UI10:--0%
L1-Fieldbus Fda02
Note:
the expansion card cannot be used to confi gure the suction
pressure probes (including the backup probes)
The expansion card is connected to the pRack pR300T via port J26 FBus
on the pRack, the same used for connecting an external driver, and port
J6BMS on the expansion card via RS485
Fig. 2.l
Only one expansion card can be used for each compressor rack and the
expansion card can only be connected to the board with pLAN address 1:
Fig. 2.m
Page 69 of 172
Copyright HPL March 2021
P4114S Rev 03
Содержание Hubbard GCU2040PXB1
Страница 4: ...Page 4 of 172 Copyright HPL March 2021 P4114S Rev 03...
Страница 44: ...4 Wiring Schematics Model GCU2040PXB1 Part Number D4155S Page 44 of 172 Copyright HPL March 2021 P4114S Rev 03...
Страница 49: ...6 Carel PR300T CO2 Controller manual Page 49 of 172 Copyright HPL March 2021 P4114S Rev 03...
Страница 144: ...Page 144 of 172 Copyright HPL March 2021 P4114S Rev 03...
Страница 161: ...8 PRESSURE ENTHALPY DIAGRAM FOR R744 REFRIGERANT Page 161 of 172 Copyright HPL March 2021 P4114S Rev 03...
Страница 165: ...9 Commissioning Form Page 165 of 172 Copyright HPL March 2021 P4114S Rev 03...