3
|
Components
Service manual
67
ATXP20~35 + FTXP20~71 + ARXP20~35 + RXP20~71
Split Comfora R32
ESIE18-01E – 2023.01
Is the problem solved?
Action
No
Return to the troubleshooting of the
specific error and continue with the
next procedure.
3.3.2 Repair procedures
To remove the expansion valve coil
Prerequisite:
Stop the unit operation via the user interface.
Prerequisite:
Turn OFF the respective circuit breaker.
Prerequisite:
Remove the required plate work, see
111].
1
If needed, remove any parts or insulation to create more space for the
removal.
2
Remove the cap (if appliccable) from the expansion valve coil.
a
a
Expansion valve coil cap
3
Pull up the expansion valve coil to remove it from the expansion valve body.
INFORMATION
It may be needed to turn the expansion valve coil 1/8 turn counter clockwise to
unlock it. Make sure to note the correct orientation (position) of the expansion valve
coil before removal.
a
b
a
Expansion valve coil
Содержание FTXP20-71L