2
|
Troubleshooting
Service manual
45
ATXP20~35 + FTXP20~71 + ARXP20~35 + RXP20~71
Split Comfora R32
ESIE18-01E – 2023.01
2.6.10 Unit discharges white mist
Check
Detail
Check installation conditions.
▪
Humid site.
▪
Dirty site.
▪
Oil mist.
Check installation conditions.
Dirty heat exchanger.
Air filter.
Dirty air filter.
Fan motor.
Defective fan motor.
2.6.11 Swing flap does not operate
Symptom
Check
Detail
Swing flap does not
operate
Check swing flap motor
Some functions can force
the swing flap into a fixed
position, although swing
mode is selected on the
remote controller. This is
not a unit error, but a
control function to
prevent draft to the
customer.
Check indoor unit PCB
Connector connection
Содержание FTXP20-71L
Страница 190: ......
Страница 191: ......
Страница 192: ...ESIE18 01E 2023 01 Copyright 2019 Daikin Verantwortung f r Energie und Umwelt...