3
|
Components
Service manual
125
ATXP20~35 + FTXP20~71 + ARXP20~35 + RXP20~71
Split Comfora R32
ESIE18-01E – 2023.01
Swing flap motor resistance
measurements are correct?
Action
Yes
Return to the troubleshooting of the
specific error and continue with the
next procedure.
No
Replace the swing flap motor, see
125].
3.11.2 Repair procedures
To remove the swing flap motor
Prerequisite:
Stop the unit operation via the user interface.
Prerequisite:
Turn OFF the respective circuit breaker.
Prerequisite:
Remove the required plate work, see
111].
1
Remove both swing flaps from the indoor unit (by clicking it out).
2
Remove the cover.
a
b
c
a
Cover
b
Screw
c
Swing flap motor
3
Disconnect the connector from the swing flap motor.
4
Remove the screw from the swing flap motor.
5
Remove the swing flap motor from the coupling piece.
6
To install the swing flap motor, see
To install the swing flap motor
1
Install the swing flap motor in the correct location on the indoor unit. Make
sure the swing flap motor shaft is correctly inserted in the coupling piece.