Function of Main Structural Parts
Si12-411A
86
Function and Control
2.2
Function of Thermistor
2.2.1 Heat Pump Model
A Outdoor Heat
Exchanger
Thermistor
(DCB)
1. An outdoor heat exchanger thermistor is used for controlling a target discharge temperature.
Set a target discharge temperature depending on an outdoor and indoor heat exchanger
temperature.
Control the electronic expansion valve opening so that the target discharge temperature can
be obtained.
2. An outdoor heat exchanger thermistor is used for detecting a disconnected discharge pipe
thermistor when cooling.
When the temperature of the discharge piping is lower than the temperature of outdoor heat
exchanger, a disconnected discharge pipe thermistor can be detected.
B Discharge
Pipe Thermistor
(DOT)
1. Discharge pipe thermistor is used to control a discharge pipe.
If the temperature of discharge pipe (used in place of the inner temperature of the
compressor) rises abnormally, the operating frequency drops or the operation must be
halted.
2. A discharge pipe thermistor is used for detecting a disconnected discharge pipe thermistor.
C Gas Pipe
Thermistor
(DGN)
1. When cooling: a gas pipe thermistor is used for gas pipe isothermal control.
Control electronic expansion valve opening so that a gas pipe temperature in each room
becomes equal.
SV
D
2
Four-way valve
1
Compressor
3
Solenoid valve
EV
B
EV
C
EV
D
EV
A
Receiver
4
Expansion valve
A
B
C
D
E
(R2435)
Содержание FTKE25BVM
Страница 1: ...C Series Applied Models zInverter Multi Cooling Only zInverter Multi Heat Pump Si12 411A...
Страница 6: ...Si12 411A Table of Contents v Index i Drawings Flow Charts v...
Страница 7: ...Si12 411A vi Table of Contents...
Страница 67: ...Specifications Si12 411A 56 Specifications...
Страница 81: ...Printed Circuit Board Connector Wiring Diagram Si12 411A 70 Printed Circuit Board Connector Wiring Diagram...
Страница 131: ...Instruction Si12 411A 120 System Configuration CDK X D 25 35 50 60 C Names of parts Indoor Unit 3 6 8 9 10 7 1 4 5 2...
Страница 173: ...Instruction Si12 411A 162 System Configuration...
Страница 227: ...Check Si12 411A 216 Service Diagnosis...
Страница 268: ...Si12 411A Others 257 Part 8 Others 1 Others 258 1 1 Test Run from the Remote Controller 258 1 2 Jumper Settings 259...
Страница 295: ...Si12 411A iv Index...
Страница 298: ...Si12 411A Printed in Singapore 03 2005 AK COS...