Si12-411A
Service Check Function
Service Diagnosis
167
3.
Service Check Function
In the
ARC433A series
, the temperature display sections on the main unit indicate
corresponding codes.
1. When the timer cancel button is held down for 5 seconds, a “
00
” indication flashes on the
temperature display section.
< Cover in open position >
2. Press the timer cancel button repeatedly until a continuous beep is produced.
The code indication changes in the sequence shown below, and notifies with along beep.
Note:
1. A short beep and two consecutive beeps indicate non-corresponding codes.
2. To cancel the code display, hold the timer cancel button down for 5 seconds. The code
display also cancels itself if the button is not pressed for 1 minute.
No.
Code
No.
Code
No.
Code
1
00
11
E7
21
UA
2
U4
12
C7
22
A5
3
F3
13
H8
23
J9
4
E6
14
J3
24
E8
5
L5
15
A3
25
P4
6
A6
16
A1
26
L3
7
E5
17
C4
27
L4
8
LC
18
C5
28
H6
9
C9
19
H9
29
H7
10
U0
20
J6
30
U2
C
O N
TEMP
ON/OFF
POWERFUL
HOME LEAVE
MODE
TIMER
FAN
SWING
SILENT
SENSOR
ON
CANCEL
OFF
Signal transmitter
It sends signals to the indoor unit.
Display
It displays the current settings.
(In this illustration, each section is
shown with all its displays ON for the
purpose of explanation.)
HOME LEAVE button
ON TIMER button
ON / OFF button
OFF TIMER button
for HOME LEAVE operation
MODE selector button
POWERFUL button
for POWERFUL operation
SILENT button
SWING button
for OUTDOOR UNIT
SILENT operation
SENSOR button
CLOCK button
for INTELLIGENT EYE operation
•
It selects the operation mode.
(AUTO / DRY / COOL / HEAT / FAN)
TIMER setting button
•
It changes the time setting.
FAN setting button
•
It selects the air flow rate setting.
TIMER CANCEL button
•
It cancels the timer setting.
TEMPERATURE
adjustment button
•
It changes the temperature setting.
•
Press this button once to start
operation.
Press once again to stop it.
(Q0344)
The figure shows the remote controller for <ARC433A1, A2>
(wall mounted 25 / 35 class).
Содержание FTKE25BVM
Страница 1: ...C Series Applied Models zInverter Multi Cooling Only zInverter Multi Heat Pump Si12 411A...
Страница 6: ...Si12 411A Table of Contents v Index i Drawings Flow Charts v...
Страница 7: ...Si12 411A vi Table of Contents...
Страница 67: ...Specifications Si12 411A 56 Specifications...
Страница 81: ...Printed Circuit Board Connector Wiring Diagram Si12 411A 70 Printed Circuit Board Connector Wiring Diagram...
Страница 131: ...Instruction Si12 411A 120 System Configuration CDK X D 25 35 50 60 C Names of parts Indoor Unit 3 6 8 9 10 7 1 4 5 2...
Страница 173: ...Instruction Si12 411A 162 System Configuration...
Страница 227: ...Check Si12 411A 216 Service Diagnosis...
Страница 268: ...Si12 411A Others 257 Part 8 Others 1 Others 258 1 1 Test Run from the Remote Controller 258 1 2 Jumper Settings 259...
Страница 295: ...Si12 411A iv Index...
Страница 298: ...Si12 411A Printed in Singapore 03 2005 AK COS...