Instruction
Si12-411A
148
System Configuration
■
Priority Room Setting
The Priority Room Setting requires initial programming during installation. Please consult your
retailer or dealer for assistance.
The room designated as the Priority Room takes priority in the following situations;
1. Operation Mode Priority
As the operation mode of the Priority Room takes precedence, the user can select a different
operation mode from other rooms.
〈
Example
〉
* Room A is the Priority Room in the examples.
When COOL mode is selected in Room A while operating the following modes in Room B,C and D :
2. Priority when POWERFUL operation is used
〈
Example
〉
* Room A is the Priority Room in the examples.
The indoor units in Rooms A,B,C and D are all operating. If the unit in Room A enters POWERFUL
operation, operation capacity will be concentrated in Room A. In such a case, the cooling (heating)
efficiency of the units in Rooms B,C and D may be slightly reduced.
3. Priority when using OUTDOOR UNIT SILENT operation
〈
Example
〉
* Room A is the Priority Room in the examples.
Just by setting the unit in Room A to SILENT operation, the air conditioner starts OUTDOOR UNIT
SILENT operation.
You don’t have to set all the operated indoor units to SILENT operation.
Operation mode in Room B, C and D
Status of Room B, C and D when the unit in Room A is in COOL mode
COOL or DRY or FAN
Current operation mode maintained
HEAT
The unit enters Standby Mode. Operation resumes when the
Room A unit stops operating.
AUTO
If the unit is set to COOL mode, operation continues. If set to
HEAT mode, it enters Standby Mode. Operation resumes when
the Room A unit stops operating.
Содержание FTKE25BVM
Страница 1: ...C Series Applied Models zInverter Multi Cooling Only zInverter Multi Heat Pump Si12 411A...
Страница 6: ...Si12 411A Table of Contents v Index i Drawings Flow Charts v...
Страница 7: ...Si12 411A vi Table of Contents...
Страница 67: ...Specifications Si12 411A 56 Specifications...
Страница 81: ...Printed Circuit Board Connector Wiring Diagram Si12 411A 70 Printed Circuit Board Connector Wiring Diagram...
Страница 131: ...Instruction Si12 411A 120 System Configuration CDK X D 25 35 50 60 C Names of parts Indoor Unit 3 6 8 9 10 7 1 4 5 2...
Страница 173: ...Instruction Si12 411A 162 System Configuration...
Страница 227: ...Check Si12 411A 216 Service Diagnosis...
Страница 268: ...Si12 411A Others 257 Part 8 Others 1 Others 258 1 1 Test Run from the Remote Controller 258 1 2 Jumper Settings 259...
Страница 295: ...Si12 411A iv Index...
Страница 298: ...Si12 411A Printed in Singapore 03 2005 AK COS...