7-13
Chapter 7
Administrator F
unctions
D
ATA
B
ACKUP
(U
TILIZATION
OF
DATA
)
A
DMINISTRATOR
F
UNCTIONS
C
HAPTER
7
7.3.2 Simplified data log function
The welding status can be checked on a computer by sampling the data during welding and backing
them up in the USB memory. Only three of the following data can be sampled.
The data types/sampling speed should be specified in the internal function F52/F53 (data log function).
(
-
Simplified data log will be created below the "DAIHEN_OTC_Welbee\DAT\DAT00001" folder. A csv
file will be created per welding.
When DAIHEN_OTC_Welbee\DAT\DAT00001 folder is already existing, "DAT00002" folder will be
created below the "DAIHEN_OTC_Welbee\DAT" folder and folder for the consecutive number will per
created for each simplified data log.
Example: The data will be output as below when the internal function F52 is set to "1" (detected values
of welding current, welding voltage and feeding speed) and F53 to "2" (100 ms).
T I P S
• The length of time that can be used for recording depends on the sampling speed. If the
sampling speed is set to 100 ms, data of approximately five hours can be recorded. When
the data exceeds the capacity, they will be deleted in order from the oldest. Also note that
data will be recorded during welding only, and not recorded when there is no output.
• The simplified data log cannot be backed up. It will be deleted when the power switch is
turned off.
The simplified data log can be exported even if an error code is displayed (error code is
output) on the left/right digital meters. In that case, back up the data before turning off the
power switch.
• Welding current set value
• Welding voltage set value
• Wire feeding speed set value
• Welding current actual value • Welding voltage actual value • Wire feeding speed actual value
Start of welding
Elapse of
time
Time [msec]
Welding current [A]
Welding current [V]
Feeding rate [m/min]
Содержание OTC Welbee WB-P320E
Страница 2: ......
Страница 8: ...TABLE OF CONTENTS vi MEMO ...
Страница 28: ...PART NAMES PRODUCT SPECIFICATION AND CONFIGURATION CHAPTER 2 2 12 ...
Страница 52: ...WIRING OF VOLTAGE DETECTION CABLE AT BASE METAL SIDE CONNECTION CHAPTER 4 4 18 ...
Страница 140: ...TROUBLESHOOTING TROUBLESHOOTING CHAPTER 9 9 6 ...