6-3
Chapter 6
W
elding Condition
L
IST
OF
W
ELDING
C
ONDITIONS
W
ELDING
C
ONDITION
C
HAPTER
6
F19
Alarm setting switching
OFF/ON
OFF
Sets the output status when an error of the alarm
level is detected:
OFF: Ineffective
ON: Stops the output
-
F20
Low input voltage
detection level
260 to 400
320 (V)
Adjusts the low primary input voltage detection
level.
-
F21
Maximum cooling fan
operation
OFF/ON
OFF
Sets the operation mode of cooling fan:
OFF: Economical operation
ON: Rotates the fan at maximum speed at all time
-
F22
Operation sound switching
OFF/ON
ON
Sets the operation sound when any key is pressed
on the operation panel:
OFF: Turns off the sound
ON: Turns on the sound
-
F23
Sleep mode
switching time
0 to 10
0
Sets the time until the welding power source
enters into sleep mode:
0: OFF
1 to 10: 1 min to 10 min
-
F24
Wire feeding speed setting
OFF/ON
OFF
Sets the criteria for welding condition:
OFF: based on current
ON: based on wire feeding speed
-
F25
External output 1 setting
0
0
Used when connecting with automatic machine
made by other manufacturer.
-
F26
External output 2 setting
F27
External output 3 setting
F28
External output 4 setting
F29
External input 1 setting
0 to 9
0
Sets the functions of input terminal of the
programmable I/O.
-
F30
External input 2 setting
0
F31
External input 3 setting
0
F32
External input 4 setting
0
F33
No function
OFF (fixed)
OFF
No functions are provided.
-
F34
F35
F36
F37
F38
Arc voltage direct detection
switching
OFF/ON
OFF
Sets the voltage direct detecting terminal on the
base metal side of the welding power source and
voltage detection terminal of the wire feeder.
OFF: ineffective
ON: effective
-
F39
Current display adjustment
(GAIN)
-20 to 20
0 (%)
Adjusts the current values displayed on the digital
meter.
-
F40
Current display adjustment
(OFFSET)
-20 to 20
0 (A)
F41
Voltage display adjustment
(GAIN)
-20 to 20
0 (%)
Adjusts the voltage values displayed on the digital
meter.
-
F42
Voltage display adjustment
(OFFSET)
-2.0 to 2.0
0.0 (V)
F43
CAN ID
1 to 16
1
Sets CAN ID numbers to be used in the PC
monitoring system, etc.
-
F44
Reading welding conditions
with remote control
OFF/ON
OFF
Sets whether to read "1" to "10" of the welding
conditions stored on the memory via the analog
remote control:
OFF: Not to read
ON: Reads
-
F45
Special crater
sequence
OFF/ON
OFF
Sets the initial condition and crater condition as
applied for a fixed period of time regardless of the
torch switch operation:
OFF: Not applied
ON: Applied (Time set by F46 and F47 is applied)
○
No.
Function Name
Setting range
Initial value
Explanation
Memory
Содержание OTC Welbee WB-P320E
Страница 2: ......
Страница 8: ...TABLE OF CONTENTS vi MEMO ...
Страница 28: ...PART NAMES PRODUCT SPECIFICATION AND CONFIGURATION CHAPTER 2 2 12 ...
Страница 52: ...WIRING OF VOLTAGE DETECTION CABLE AT BASE METAL SIDE CONNECTION CHAPTER 4 4 18 ...
Страница 140: ...TROUBLESHOOTING TROUBLESHOOTING CHAPTER 9 9 6 ...