4-3
Chapter 4
Connection
C
ONNECTING
THE
W
ELDING
P
OWER
S
OURCE
C
ONNECTION
C
HAPTER
4
4.2.1 Connection of cable at output side
This section explains the procedure for connecting of cable at output side.
1.
Connect the power cable for base metal side to the output terminal (base metal side) and base
metal.
●
At the welding power source side, fit the convex part of the connector and concave part of the output
terminal for secure connection and tighten them in the clockwise direction.
2.
Connect the power cable for torch side to the output terminal (torch side).
●
Connect the connectors as same as above.
Connection for cable at output side is complete. Procedure is followed by 4.2.2
-
• Use a grounding cable for the case, of welding power source and perform grounding.
Otherwise, voltage may increase in the case or base metal which could cause electric
shock.
Connector
Power cable for
base metal side
Base metal
Power cable for torch side
Output terminal
(Torch side)
Output terminal
(Base metal side)
Welding power source
Ground a base metal if
required by local law.
Содержание OTC Welbee WB-P320E
Страница 2: ......
Страница 8: ...TABLE OF CONTENTS vi MEMO ...
Страница 28: ...PART NAMES PRODUCT SPECIFICATION AND CONFIGURATION CHAPTER 2 2 12 ...
Страница 52: ...WIRING OF VOLTAGE DETECTION CABLE AT BASE METAL SIDE CONNECTION CHAPTER 4 4 18 ...
Страница 140: ...TROUBLESHOOTING TROUBLESHOOTING CHAPTER 9 9 6 ...