6-47
Chapter 6
W
elding Condition
S
ETTING
I
NTERNAL
F
UNCTIONS
W
ELDING
C
ONDITION
C
HAPTER
6
6.7.2.44 F67: Setting change of current value (initial condition, crater condition)
When “CRATER ON” is selected, the current value of the initial condition and the crater condition can
be set in percentage based on the current value of the welding condition.
•
[ON]: enables the function.
Set the current value of the initial condition with F68, and set the current value of the crater condition with
F69.
•
[OFF]: disables the function.
6.7.2.45 F68: Setting of current value (initial condition)
The current value of the initial condition can be set in percentage based on the current value of the
welding condition.
•
Setting range of current value (initial condition): 10 % to 300
%
6.7.2.46 F69: Setting of current value (crater condition)
The current value of the crater condition can be set in percentage based on the current value of welding
condition.
•
Setting range of current value (crater condition): 10 % to 300 %
6.7.2.47 F77
:
Welding result control function identification numbers
Sets the identification numbers of welding power source when using welding result control function.
The identification number set in this function become the part of file name when backing up the data of
welding result control function. (
Welding Result Control Function)
•
Setting range of identification number: 1 to 999.
Содержание OTC Welbee WB-P320E
Страница 2: ......
Страница 8: ...TABLE OF CONTENTS vi MEMO ...
Страница 28: ...PART NAMES PRODUCT SPECIFICATION AND CONFIGURATION CHAPTER 2 2 12 ...
Страница 52: ...WIRING OF VOLTAGE DETECTION CABLE AT BASE METAL SIDE CONNECTION CHAPTER 4 4 18 ...
Страница 140: ...TROUBLESHOOTING TROUBLESHOOTING CHAPTER 9 9 6 ...