S
ETTING
I
NTERNAL
F
UNCTIONS
W
ELDING
C
ONDITION
C
HAPTER
6
6-28
Stuck wire removal voltage
(*1)
Voltage is not output.
Voltage is output for approx. 0.2 seconds after completion of
anti-stick process.
Welding current/voltage
setting
Set by operation panel or
remote control.
Set by external command
voltage(*2)
Set by operation panel or
remote control.
Inching
Operation by operation panel
or remote control.
Set on the operation panel or short-circuit the pins [5]-[6] of the
analog remote control receptacle (CON2).
<Analog remote control receptacle> (*5)
The above figure shows the front view of analog remote control
receptacle which is allocated on the front of welding power
source.
Retract function (*3)
Disabled
Enabled
Error reset
After removing the cause of
error, the power is restored.
After removing the cause of error, the power is restored.
Or open/short-circuit the deactivated terminal pins [3]-[4] of the
external connection terminal block TM3. (*4)
*1: In the "Auto" mode, voltage to release welding is output for approx. 0.2 seconds after the anti-stick process. This
voltage is output even if the wire is not welded.
*2: If an external command voltage is input, it should be input to the terminal pins ([1]-[3], [1]-[4]) of the remote
control receptacle as shown in the below figure.
Relationship between input and output is as the charts provided in "F5: Maximum external command voltage
-
".
(
-
F5: Maximum external command voltage)
Ensure that the command voltage is input at least 100 ms before the start signal is input.
Use the external power source with current capacity of 0.5 mA or more.
• Supply 0V to 15 V to E1 and E2.
Exceeding 15 V may result in damage to the control circuit of the welding power
source.
*3: In the "Auto" mode, "3" (Retract) can be allocated to the functions of external input terminals of F29 - F32.
For more information on the retract function, refer to (
-
F29 to F32: External input terminal setting)
*4: For the details of external connection terminal block; (
Connection of automatic machine
)
*5: For the applicable plug of analog remote control receptacles: See specification DPC25-6A/Part No. 4730-009.
Parameter
Setting
0 (Semi-automatic)
1 (Automatic machine 1)
2 (Automatic machine 2)
! "
#
$
2
5
6
E2
(Welding current)
E1
(Welding current)
External power source
0 to 15 V,
0.5 mA or more capacity
1
3
4
Analog remote control
+
+
receptacle (*5)
Содержание OTC Welbee WB-P320E
Страница 2: ......
Страница 8: ...TABLE OF CONTENTS vi MEMO ...
Страница 28: ...PART NAMES PRODUCT SPECIFICATION AND CONFIGURATION CHAPTER 2 2 12 ...
Страница 52: ...WIRING OF VOLTAGE DETECTION CABLE AT BASE METAL SIDE CONNECTION CHAPTER 4 4 18 ...
Страница 140: ...TROUBLESHOOTING TROUBLESHOOTING CHAPTER 9 9 6 ...