W
ELDING
R
ESULT
C
ONTROL
F
UNCTION
A
DMINISTRATOR
F
UNCTIONS
C
HAPTER
7
7-6
7.2.2.2
Wire consumption
Wire consumption is controlled according to the setting range.
•
P20 (Cumulative wire consumption used in welding)
Wire consumption (kg) used in welding is measured and counted.
The setting range of count value is between 0 and 999 kg. The count value will be cleared according to the
"P22" setting.
(If continuous operation is enabled, the value will be cleared when exceeding 999 and returns to 0.)
T I P S
• Approximate wire consumption will be obtained with the wire consumption control
function.
The table below shows the wire unit amount (g/m) calculated from the specific gravity
(g/cm
3
) of the wire material. Wire consumption is calculated based on the unit amount
and the wire feeding amount during welding. Therefore, there will be differences
between the actual consumption and the calculated value depending on the wire
constituents.
• When wire consumption is 100 kg or lower, the value after the decimal point is also
displayed.
• The wire consumption used in inching or wire slowdown is not measured.
• Special wires not listed in the table below are not measured.
•
P21 (Target wire consumption)
Select the target value of wire consumption in the range from 0 to 999 kg.
When the "P20" count value reaches the wire consumption specified here, an alarm appears indicating that
the target is achieved. (
-
Alarm indication when target is achieved)
•
P22 (Operation at the time when the target wire consumption is achieved)
Select the operation from 0 to 5 for the time when the target specified for "P21" is achieved.
The set values and operations when the target is achieved are the same as those of the "P12" function. "P12
(Operation at the time when the target number of welding points is achieved)" (
-
Operation
Set value
0
1
2
3
4
5
The count value is cleared when the target is achieved
(*1)
Yes
No
Yes
No
No
No
Operation is continued after the target is achieved (*2)
Enable
Enable
Enable
Enable
Disabled Disabled
The count value is cleared when the power is turned on
Yes
Yes
No
No
Yes
No
*1: When an alarm is displayed, pressing any key of the operation panel can also clear the count value.
*2: If "Disabled" is selected and the target is achieved, next welding cannot start until any key on the operation panel
is pressed.
Wire diameter (mm)
Unit amount (g/m)
Mild steel solid
Stainless steel
Cored
0.6
2.2
-
-
0.8
3.9
4.0
-
0.9
5.0
5.1
4.2
1.0
6.2
6.3
-
1.2
8.9
9.0
7.4
1.4
12.1
-
10.1
1.6
15.8
15.9
13.2
Содержание OTC Welbee WB-P320E
Страница 2: ......
Страница 8: ...TABLE OF CONTENTS vi MEMO ...
Страница 28: ...PART NAMES PRODUCT SPECIFICATION AND CONFIGURATION CHAPTER 2 2 12 ...
Страница 52: ...WIRING OF VOLTAGE DETECTION CABLE AT BASE METAL SIDE CONNECTION CHAPTER 4 4 18 ...
Страница 140: ...TROUBLESHOOTING TROUBLESHOOTING CHAPTER 9 9 6 ...