6.2 Function on Operation Panel
This section explains the function of displays and keys arranged on the operation panel.
F62
Base current fine
adjustment
-60 to 60
0 (A)
Sets the adjustment value of base current in pulse
welding.
○
F63
L pulse peak current fine
adjustment
-150 to 150
0 (A)
Sets the adjustment value of pulse peak current
at the LOW side in pulse welding.
○
F64
L pulse peak time fine
adjustment
-1.5 to 1.5
0.0 (ms)
Sets the adjustment value of pulse peak time at
the LOW side in pulse welding.
○
F65
L-base current fine
adjustment
-60 to 60
0 (A)
Sets the adjustment value of base current at the
LOW side in pulse welding.
○
F66
Feeding amplitude ratio
adjustment
0 to 100
50 (%)
Sets the feeding amplitude ratio of wire feeder
speed in wave pulse welding.
○
F67
Setting change of current
value (initial condition, crater
condition)
OFF/ON
OFF
When “CRATER ON” is selected, sets the current
value of the initial condition and crater condition
in the percentage based on the current value of
the welding condition.
OFF: invalid
ON: settable with percentage
-
F68
Setting of current value
(initial condition)
10 to 300
100 (%)
Sets the current value of the initial condition in the
percentage based on the current value of the
welding condition.
-
F69
Setting of current value
(crater condition)
10 to 300
100 (%)
Sets the current value of the crater condition in
the percentage based on the current value of the
welding condition.
-
F77
Welding power source
identification numbers
1 to 999
1
Sets welding power source identification numbers
of Welding result control function.
-
No.
Name
Function
1
Left digital meter
Displays various information.
• The welding current is displayed in welding, and the LED of "A" lights up.
• In each setting, corresponding setting values are displayed, and the LED lit position
automatically switches.
No.
Function Name
Setting range
Initial value
Explanation
Memory
Is
IE
I
F
A
m/min.
V
s
A
V
s
㸣
V
sec.
Hz
m/min.
JOB No.
SYN.
INDIV.
SYNERG.
WAVE
(3 sec.)
LOAD
SAVE
ARC
START
ENTER
0.8
1.0
1.2
MAG(20 CO
2
)
MIG(2.5 CO
2
)
MIG(Ar)
DC PULSE
DC
G3Si1
CrNi
29
16
9
8
7
24
25
26
4
5
1
2
27
6
17
18
19
23
3
21
22
15
14
13
12
11
28
10
20
Содержание OTC Welbee WB-P320E
Страница 2: ......
Страница 8: ...TABLE OF CONTENTS vi MEMO ...
Страница 28: ...PART NAMES PRODUCT SPECIFICATION AND CONFIGURATION CHAPTER 2 2 12 ...
Страница 52: ...WIRING OF VOLTAGE DETECTION CABLE AT BASE METAL SIDE CONNECTION CHAPTER 4 4 18 ...
Страница 140: ...TROUBLESHOOTING TROUBLESHOOTING CHAPTER 9 9 6 ...