D
ATA
B
ACKUP
(U
TILIZATION
OF
DATA
)
A
DMINISTRATOR
F
UNCTIONS
C
HAPTER
7
7-16
7.3.6 Importing backup data
This section explains how to import the backup data.
NOTE
• The data stored in the welding power source will be overwritten by the backup data. Make
sure of it before overwriting.
1.
Turn on the power switch.
2.
Insert the USB flash drive to the USB connector of the operation panel.
3.
Press the SAVE key.
4.
Turn the parameter adjusting knob counterclockwise to display "USb" on the left digital meter.
5.
Select the data to import.
6.
Press the SAVE key.
7.
Press the ENTER key.
⇒
The LED of SAVE key lights up.
●
Turn the parameter adjusting knob further
counterclockwise to display the data to import on
the right digital meter.
⇒
The display changes in order of "ALL" -> "1" -> "2".
⇒
"ALL" means that all the data ("1" to "2") available for
importing are selected.
⇒
Details of the numbers displayed (
⇒
The LED of ENTER key flashes.
⇒
Importing the backup data starts. During backup,
the display of right digital meter changes.
⇒
When importing is completed, "End" will be
displayed on the right digital meter.
SAVE
SAVE
A
V
s
㸣
m/min.
sec.
JOB No.
Hz
SAVE
ENTER
㧔
3 sec
㧕
A
V
s
㸣
m/min.
sec.
JOB No.
ENTER
㸦
3 sec.
㸧
Hz
Содержание OTC Welbee WB-P320E
Страница 2: ......
Страница 8: ...TABLE OF CONTENTS vi MEMO ...
Страница 28: ...PART NAMES PRODUCT SPECIFICATION AND CONFIGURATION CHAPTER 2 2 12 ...
Страница 52: ...WIRING OF VOLTAGE DETECTION CABLE AT BASE METAL SIDE CONNECTION CHAPTER 4 4 18 ...
Страница 140: ...TROUBLESHOOTING TROUBLESHOOTING CHAPTER 9 9 6 ...