7-11
Chapter 7
Administrator F
unctions
D
ATA
B
ACKUP
(U
TILIZATION
OF
DATA
)
A
DMINISTRATOR
F
UNCTIONS
C
HAPTER
7
7.3.1 Setting of welding conditions/internal functions
The following contents can be stored in the "DAIHEN_OTC_WELDING_PRAMETER.CSV" file.
•
All the welding condition data recorded in memory
•
The internal function values at the time of data backup
The current welding conditions set with the operation panel will not be saved. (If necessary, record them
in memory beforehand.)
The welding condition data recorded in the memory will be output in the way that the JOB Nos.
(registration Nos.) are displayed in a vertical line and the parameter values in a horizontally line.
Column
Item
Description
Unit Column
Item
Description
Unit
A
job_num
JOB No.
-255 to -155,
1 to 100
AA
wmode_H
Process information
1
(*2)
B
spot_tim
Arc Spot
time
0.1(s)
AB
wmode_L
Process information
2
(*2)
C
prf_tim
Pre-flow time
0.1(s)
AC
pre_feed
Initial feed speed
0.1(m/min)
D
pre_iset
Initial current
1(A)
AD
wld_feed
Welding feed speed
0.1(m/min)
E
pre_vset
Initial voltage
0.1(V)
AE
cre_feed
Crater feed speed
0.1(m/min)
F
pre_uni_vset
Initial voltage
(synergic)
1(±)
AF
ant_tim_adj
Anti-stick time
adjustment
0.01(s)
G
wld_iset
Welding current
1(A)
AG
ant_vset_adj
Anti-stick voltage
adjustment
0.1(V)
H
wld_vset
Welding voltage
0.1(V)
AH
sldwn_adj
Slowdown
adjustment
0.1(m/min)
I
wld_uni_vset
Welding voltage
(synergic)
1(±)
AI
up_slp_tim
Up-slope
time
0.1(s)
J
cre_iset
Crater current
1(A)
AJ
dwn_slp_tim
Down-slope
time
0.1(s)
K
cre_vset
Crater voltage
0.1(V)
AK
pre_tim
initial time
0.1(s)
L
cre_uni_vset
Crater voltage
(synergic)
1(±)
AL
cre_tim
crater time
0.1(s)
M
aff_tim
Post-flow time
0.1(s)
AM
KubireAutoAdj
Automatic
correction of
[squeeze]
0/1(OFF/ON)
N
arc_char
Arc characteristics
1(±)
AN
KubireAutoSave
Saving [squeeze]
-
O
wave_frq
Wave frequency
0.1(Hz)
AO
KubireP1P
Spatter control P1P
1(±)
P
arc_char2
Arc characteristics
(reserved)
-
AP
KubireP2P
Spatter control P2P
1(±)
Q
pre_sens_slp
[Squeeze]
detection
sensitivity
(reserved)
-
AQ
PerIset
(reserved)
-
R
pre_sens_cnst
-
-
AR
PreIsetPer
(reserved)
-
"-" is shown for unused condition numbers.
Parameter of condition No.1
Parameter value
JOB No.
Содержание OTC Welbee WB-P320E
Страница 2: ......
Страница 8: ...TABLE OF CONTENTS vi MEMO ...
Страница 28: ...PART NAMES PRODUCT SPECIFICATION AND CONFIGURATION CHAPTER 2 2 12 ...
Страница 52: ...WIRING OF VOLTAGE DETECTION CABLE AT BASE METAL SIDE CONNECTION CHAPTER 4 4 18 ...
Страница 140: ...TROUBLESHOOTING TROUBLESHOOTING CHAPTER 9 9 6 ...