7
-24
Apr. 2007
DSC48
4.5 TROUBLESHOOTING
Symptom
Cause
Action
The automatic feeding depth
control function does not
operate and the automatic
feeding depth control lamp
does not come on.
• The check lamp does not operate correctly when
turning the ignition switch.
- The MICOM unit is not supplied with power.
- Or faulty ground of the MICOM unit
• Faulty input signal from the automatic feeding depth
control switch
• Power to MICOM unit
• Ground of MICOM unit
• Input signal wire
The automatic feeding depth
control lamp does not come
on (though the function
operates).
• Power is not supplied to the automatic feeding
depth control lamp.
• Blown lamp bulb
• Power
• Replacement
The automatic feeding depth
control lamp comes on but
the automatic feeding depth
control function does not
operate.
• There is no relay sound from the threshing controller
when either the deep and shallow control is engaged.
- Faulty input signal from the threshing switch (open
circuit)
- Faulty input signal from the straw sensor (open
circuit)
- Faulty input signal from the reverse switch
(ground)
- Faulty input signal from the neutral switch (open
circuit)
- Faulty input signal from the vehicle speed sensor
(open circuit)
- Faulty input signal from the grain sensors S1·S2
- Defective limit switch (manual operation
unavailable as well)
• There is relay sound from the threshing controller
when either the deep and shallow control is
engaged.
- Faulty feeding depth control motor to power (open
circuit)
- Faulty feeding depth control motor to ground
(open circuit)
- Defective feeding depth control motor
• Input signal wire
• Input signal wire
• Input signal wire
• Input signal wire
• Input signal wire
• Input signal wire
• Replace
• Connector to main wiring
of threshing controller
• Power to feeding depth
control motor
• Ground of feeding depth
control motor
• Replace
The Deep (or "Shallow")
function does not operate.
• Only manual operation is available.
- Defective wiring or connector between the deep
relay coil (or shallow relay coil) and MICOM unit
(open circuit)
- Faulty input signal from the grain sensors S1 or S2
• Connector to main wiring
of threshing controller
• Power
• Input signal wire
• Even manual operation is unavailable.
- No power is supplied to the feeding depth control
relay (shallow relay).
• Open circuit in the deep (shallow) relay coil
• Defective deep (shallow) limit switch
(no continuity)
• Power
• Connector to main wiring
of threshing controller
• Connector of threshing
controller
• Replace limit switch
The feeding depth does not
change to either "Standard"
or "Deep" after the feeding
depth selection switch is
set in the "Standard" or
"Shallow" position.
• Faulty input signal from the feeding depth selection
switch
• Input signal wiring
Содержание DSC48
Страница 1: ...DSC48 COMBINE HARVESTER WORKSHOP MANUAL...
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 8: ......
Страница 38: ...MEMO...
Страница 40: ......
Страница 106: ......
Страница 136: ...MEMO...
Страница 138: ......
Страница 140: ......
Страница 160: ...MEMO...
Страница 162: ......
Страница 196: ...MEMO...
Страница 198: ......
Страница 216: ......
Страница 251: ...Apr 2007 7 11 DSC48 2 3 WIRING DIAGRAM 417W717A...
Страница 262: ...7 22 Apr 2007 DSC48 4 3 WIRING DIAGRAM 417W723A...
Страница 281: ...417W758B B ON GND B GND 7 2 CIRCUIT DIAGRAM Apr 2007 7 41 DSC48...
Страница 282: ......
Страница 285: ...DSC48 INDEX...