DWS-3160 Series Gigabit Ethernet Unified Switch CLI Reference Guide
335
specific port/VLAN. The rate is specified in packets per second. The packets that exceed the
limit will be dropped.
no_limit
- Configure the rate of the IGMP control packet to be unlimited that the Switch can
process on a specific port/VLAN. The rate is specified in packets per second. The packets that
exceed the limit will be dropped. The default setting is no_limit.
Restrictions
Only Administrators, Operators and Power-Users can issue this command.
Example
To configure the IGMP snooping per port rate_limit:
DWS-3160-24PC:admin# config igmp_snooping rate_limit ports 1 100
Command: config igmp_snooping rate_limit ports 1 100
Success.
DWS-3160-24PC:admin#
32-3
config igmp_snooping querier
Description
This command is used to configure the time in seconds between general query transmissions, the
maximum time in seconds to wait for reports from members, and the permitted packet loss that
guarantees IGMP snooping.
Format
config igmp_snooping querier [vlan_name <vlan_name 32> | vlanid <vlanid_list> | all]
{query_interval <sec 1-65535> | max_response_time <sec 1-25> | robustness_variable
<value 1-7> | last_member_query_interval <sec 1-25> | state [enable | disable] | version
<value 1-3>}(1)
Parameters
vlan_name
- Specifies the name of the VLAN for which IGMP snooping querier is to be
configured.
<vlan_name 32>
- Enter the VLAN name here. The VLAN name can be up to 32 characters
long.
vlanid
- Specifies the VLAN ID for which IGMP snooping querier is to be configured.
<vlanid_list>
- Enter the VLAN ID list here.
all
- Specifies all VLANs for which IGMP snooping querier is to be configured.
query_interval
- (Optional) Specifies the amount of time in seconds between general query
transmissions. The default setting is 125 seconds.
<sec 1-65535>
- Enter the query interval value here. This value must between 1 and 65535
seconds.
max_reponse_time
- (Optional) Specifies the maximum time in seconds to wait for reports from
members. The default setting is 10 seconds.
<sec 1-25>
- Enter the maximum response time value here. This value must be between 1
and 25 seconds.
robustness_variable
- (Optional) Provides fine-tuning to allow for expected packet loss on a
Содержание DWS-3160-24TC
Страница 1: ......
Страница 13: ...DWS 3160 Series Gigabit Ethernet Unified Switch CLI Reference Guide 9 R refresh the displayed pages ...
Страница 271: ...DWS 3160 Series Gigabit Ethernet Unified Switch CLI Reference Guide 267 ...
Страница 586: ...DWS 3160 Series Gigabit Ethernet Unified Switch CLI Reference Guide 582 ...
Страница 766: ...DWS 3160 Series Gigabit Ethernet Unified Switch CLI Reference Guide 762 ...