Sensor adjustment with Teach-in procedure

Set detect point

Place object at position 

Press push-button for about

3 s until LEDs flash 

simultaneously 

both LEDs:

flash 
mutually

Press push-button for 

about 1 s

Set window mode

Place object at position 

Press push-button for about

3 s until LEDs flash 

simultaneously 

both LEDs:

Place object at position 

Press push-button for 

about 1 s

flash 
mutually

Set two way reflective 

barrier

Set NOC/NCC

Enable/disable Teach-in

push-button

Switch off power supply

Place reflector at position 

Press push-button for about

3 s until LEDs flash 

simultaneously 

Press button for about 13 s

until LEDs flash 

mutually 

both LEDs:

flash 
mutually

Press push-button for 

about 10 s

green LED:

yellow LED:

To change output characte-

ristic press push-button 

for about 1 s

While pressing the push-

button switch on power

supply

Keep push-button pressed

for about 3 s until both

LEDs flash simultaneously 

flashes

on:

 NOC

off:

 NCC

green LED:

yellow LED:

flashes

on:

 push-button 

      enabled

off:

 push-button 

      disabled

To enable/disable Teach-in

press push-button 

for about 1 s

Reset to factory setting

Switch off power supply

While pressing the push-

button switch on power

supply

Keep push-button pressed

for about 13 s until both

LEDs stop flashing 

Normal operating mode

Wait for 10 s

Wait for 10 s

Normal operating mode

Operating Instructions

zws-7/CD/QS

zws-7/CE/QS

zws-15/CD/5ms.a

zws-15/CE/5ms.a

Fast ultrasonic proximity switch
with one switched output

Product Description

The zws sensor offers a non-contact
measurement of the distance to an
object which must be positioned
within the sensor’s detection zone.

Ultrasonic Sensors

The switched output is set in depen-
dence of the adjusted detect dis-
tance.
Due to the short response time and
the high switching frequency these
zws sensors are applicable to the de-
tection of quick processes. For the
zws-7, the faster variant, please see
the notes for installation and operati-
on.
Via the push-button, the detect dis-
tance and operating mode can be
adjusted (teach-in). Two LEDs indi-
cate operation and the state of the
switched output.

Safety Notes

Read the operating instructions
prior to start-up.

Connection, installation and
adjustment works may only be
carried out by expert personnel.

No safety component in accor-

dance with the EU Machine Direc-
tive.

Installation

Mount the sensor at the installa-
tion site with the aid of the
enclosed mounting plate.
Maximum torque of attachment
screw: 0,5 Nm

 

 

Fig. 1:  Attachment with mounting plate

 

Connect a connection cable to the
M8 device plug.

 Avoid mechanical load on the con-

nector.

Start-Up

Connect the power supply.

Carry out the adjustment in
accordance with the diagram.

  

 
Fig. 2: Pin assignment with view onto sensor

plug and colour coding of the
microsonic connection cable

Factory Setting

Operation with one detect point

Switched output on NOC

Detect points at operating range

1
3

colour

+U

B

-U

B

brown
blue

4
2

D

Sync

black
white

1

4

3

2

Operating modes

Three operating modes are available
for the switched output:

Operation with one detect point

The switched output is set if the ob-
ject falls below the set detect point.

Window mode

The switched output is set if the ob-
ject is within the set window mar-
gins.

Two-way reflective barrier

The switched output is set if the ob-
ject is between sensor and reflector.

Synchronization

You can synchronize as many sensors
as you like.

Apply a square-wave signal  to the
sync-input  with pulse width t

i

 and

repetition rate t

(Fig.3 and

technical data). 

Fig.3: External synchronization signal

A high level on the sync-input will
deactivate the sensor.

Checking operation mode

In normal mode shortly press the
push-button.

The green LED stops shining for one
second, then it will show the current

operating mode:

1 x flashing = operation with one

switching point

2 x flashing = window mode
3 x flashing = reflective barrier
After a break of 3 s the green LED
shows the  

output function:

1 x flashing = NOC
2 x flashing = NCC

Maintenance

microsonic sensors are maintenance-
free. In case of excess caked-on dirt
we recommend cleaning the white
sensor surface

Notes

The zws sensor has a blind zone,
within which distance measure-
ments are not possible. 

In the normal operating mode, an il-
luminated yellow LED signals the
switched output is switched
through.

The sensor got to know the
distance to the object at the teach-
in stage. For objects that move into
the sound field from the side, an 8-
10 % greater distance should be
set for reliable object detection by
the sensor. 

  

Fig. 4: Setting the switching point

The zws-7 has a very short measu-
rement cycle time of only 2 ms.
Under unfavourable conditions
this can lead to the sensor wrongly

Sensor disabled

Sensor disabled

Start

+U

B

-U

B

 t

i

  

 t

p

 

Further settings

Set switched output