DWS-3160 Series Gigabit Ethernet Unified Switch CLI Reference Guide
518
Parameters
None.
Restrictions
None.
Example
To display the standalone device environment:
DWS-3160-24PC:admin#show environment
Command: show environment
Internal Power : Active
External Power : Fail
Right Fan 1 : Speed Low (3000 RPM)
Right Fan 2 : Speed Low (3000 RPM)
Right Fan 3 : Speed Low (3000 RPM)
Right Fan 4 : Speed Low (3000 RPM)
Current Temperature(Celsius) : 30
Fan High Temperature Threshold(Celsius) : 40
Fan Low Temperature Threshold(Celsius) : 35
High Warning Temperature Threshold(Celsius) : 79
Low Warning Temperature Threshold(Celsius) : 11
DWS-3160-24PC:admin#
52-3
config temperature threshold
Description
This command is used to configure the warning threshold for high and low temperature. When the
temperature is above the high threshold limit or below the low threshold limit, the Switch will send
out alarm traps or automatically shut the Switch system down.
Format
config temperature threshold {high <temperature -500-500> | low <temperature -500-500>}
Parameters
threshold
- Specifies the high and low threshold value.
high
- (Optional) Specifies to configure the high threshold value. The high threshold must
bigger than the low threshold.
<temperature -500-500>
- Enter the high threshold temperature here. This value must be
between -500 and 500.
low
- (Optional) Specifies to configure the low threshold value.
<temperature -500-500>
- Enter the low threshold temperature here. This value must be
between -500 and 500.
Содержание DWS-3160-24TC
Страница 1: ......
Страница 13: ...DWS 3160 Series Gigabit Ethernet Unified Switch CLI Reference Guide 9 R refresh the displayed pages ...
Страница 271: ...DWS 3160 Series Gigabit Ethernet Unified Switch CLI Reference Guide 267 ...
Страница 586: ...DWS 3160 Series Gigabit Ethernet Unified Switch CLI Reference Guide 582 ...
Страница 766: ...DWS 3160 Series Gigabit Ethernet Unified Switch CLI Reference Guide 762 ...