![CTC Union GSi 600 Series Скачать руководство пользователя страница 97](http://html1.mh-extra.com/html/ctc-union/gsi-600-series/gsi-600-series_installation-and-maintenance-manual_2693362097.webp)
97
CTC GSi 600
65
60
55
50
45
40
35
30
25
20
ºC
1.
2.
1.
3.
65
60
55
50
45
40
35
30
25
20
ºC
Drying period
Off (Off/1/2/3)
Applies to Heating circuit 1. Drying period for newly built
properties. The function limits the calculation of primary
flow temperature (setpoint) for "Your home’s heating
settings" to the schedule below.
Mode 1 - Drying period for 8 days
1. The setpoint of the radiator system is set to 25 °C for
4 days.
2. On Days 5-8, the set value in "Drying period
temp. °C" is used.
(From Day 9 onwards the value is calculated
automatically according to "Your home’s heating
settings")
Mode 2 - Drying period for 10 days + stepped
increased and decrease
1. Stepped increase start: The setpoint of the radiator
system is set to 25 °C. The setpoint is then raised
by 5 °C each day until it is equal to the "Drying
period temp °C". The final step may be less than 5
°C.
2. Drying period for 10 days.
3. Stepped decrease: After the stepped increase and
10 days at an even temperature, the temperature
setpoint is reduced to 25 °C in daily 5 °C stages. The
final step may be less than 5 °C.
(Following the stepped decrease and 1 day at
the setpoint of 25 °C, the value is calculated
automatically according to "Your home’s heating
settings").
Mode 3
In this mode, the function starts in “Mode 1” followed by
“Mode 2” and lastly by "Your home’s heating settings".
Drying period temp °C
25 (25...55)
The temperature for “Mode 1/2/3” as shown above is
set here.
Drying period mode
Off (Off/On)
This menu bar is displayed for Heating Circuit 2 if a
heating mode (1-3) is selected in the "Drying period
mode" menu above.
The "On" option means that the drying period mode
selected for Heating Circuit 1 will also be run for Heating
Circuit 2.
Example Drying period temperature day 1 of 12 with current set
point of 25 °C.
Day
1 2 3 4 5 6 7 8 9
and
so
on...
“Y
our home’
s heating
settings”
Example of Mode 1 with set value "Drying period temp °C": 38.
2. 10 days
Example of Mode 2 with set value for "Drying period temp °C": 37.
1 2
3 4 5 6 7 8 9 10 11 12 13 and so on...
Day
Содержание GSi 600 Series
Страница 26: ...26 CTC GSi 600 CTC GSi 616 CTC GSi 608 GSi 612 qw l min qw l min 6 1 8 Pressure differential diagram hot side ...
Страница 31: ...31 CTC GSi 600 Y60 B2 G2 Y2 G2 B15 B11 6 1 15 Schematic diagram passive cooling alt 1 common cooling heating ...
Страница 33: ...33 CTC GSi 600 B15 B12 B11 B2 G2 G2 Y2 6 1 17 Schematic diagram passive cooling alt 3 ...
Страница 64: ...8 22 HP cooling module schematic diagram 3x400V A5 ...
Страница 65: ...8 23 HP cooling module schematic diagram 1x230V 3x230V A5 ...
Страница 67: ...M GF B25 B26 Y21 B5 G20 B24 B23 B27 B28 G11 G5 B102 B18 ...
Страница 131: ...131 CTC GSi 600 ...
Страница 132: ......
Страница 133: ......
Страница 134: ......
Страница 135: ......
Страница 136: ...Enertech AB P O Box 309 SE 341 26 Ljungby Sweden www ctc se www ctc heating com 162 505 58 1 2020 09 16 ...