13.1
Information messages
Information messages are displayed when appropriate and are intended to inform
users about various operational situations.
[I002] HC1 Heating off
[I005] HC2 Heating off
Indicates that the product is in Summer mode. No need
for heating in the current heating system, only hot water.
[I008] Tariff HP off
Indicates that Tariff has switched off the heat pump.
[I009] Compressor blocked
The compressor is set to be shut down, e.g. before
drilling or digging has been carried out for the collector
coils. The product comes with the compressor switched
off. This option is selected in the "Installer/Settings/Heat
Pump" menu.
[I010] Tariff EL Off
Indicates that Tariff has switched off the electric heater.
[I011] Round circulation
Indicates that Round circulation is active. Round
circulation is a device which can be fitted by an
electricity supplier in order to disconnect equipment with
a high rate of electricity consumption for a short period
of time. Not currently in use in the UK. The compressor
and electrical output are blocked when Round
circulation is active.
[I012] High curr., reduced elec.
• The property’s main fuses risk being overloaded
due to, for example, the simultaneous use of
several power-hungry appliances. The product
reduces the electric heater’s electrical output
during this period.
• 2h max. 6 kW. Electric heating elements are
limited to 6 kW for 2 hours after being switched
on. This message appears if more than 6 kW
are required during the product's first 2 hours of
operation. This is applicable after a power outage
or a new installation.
[I013] Start delay
The compressor is not allowed to start too quickly after
it has stopped. The delay is usually at least 10 minutes.
[I014] Drying period active, d
Indicates that the floor function is active and displays the
time (days) remaining that the function will be active.
[I017] SmartGrid: Block
[I019] SmartGrid: Low price
[I018] SmartGrid: Overcapacity
Product functionality is governed by "SmartGrid". Also
refer to the "Installer/Define/Remote Control/SmartGrid"
menu.
[I021] Ext. Ctrl Heating HC1
[I022] Ext. Ctrl Heating HC2
Remote control governs whether the heat in the heating
system is to be switched on or off. If the heating is
switched off, "Heating off, heating circuit 1/2" is also
displayed.
[I028] Holiday period
Displayed when setting the holiday schedule, which
entails lowering the room temperature and that no hot
water is produced.
Содержание GSi 600 Series
Страница 26: ...26 CTC GSi 600 CTC GSi 616 CTC GSi 608 GSi 612 qw l min qw l min 6 1 8 Pressure differential diagram hot side ...
Страница 31: ...31 CTC GSi 600 Y60 B2 G2 Y2 G2 B15 B11 6 1 15 Schematic diagram passive cooling alt 1 common cooling heating ...
Страница 33: ...33 CTC GSi 600 B15 B12 B11 B2 G2 G2 Y2 6 1 17 Schematic diagram passive cooling alt 3 ...
Страница 64: ...8 22 HP cooling module schematic diagram 3x400V A5 ...
Страница 65: ...8 23 HP cooling module schematic diagram 1x230V 3x230V A5 ...
Страница 67: ...M GF B25 B26 Y21 B5 G20 B24 B23 B27 B28 G11 G5 B102 B18 ...
Страница 131: ...131 CTC GSi 600 ...
Страница 132: ......
Страница 133: ......
Страница 134: ......
Страница 135: ......
Страница 136: ...Enertech AB P O Box 309 SE 341 26 Ljungby Sweden www ctc se www ctc heating com 162 505 58 1 2020 09 16 ...