12.9.9 Settings Current sensor
These menu bars are displayed if "Current Sensor" is
defined in the "Installer/Define Current Sensor" menu.
In the menu, specify the phases (L1, L2 and L3) to
which the current sensors have been connected.
In the lower left corner of the screen, "Invalid
configuration" will be displayed until L1, L2, and L3 are
paired with the three current sensors in the menu.
When activating the "Auto config. Current Sensor"
function, it is important that you have switched off
all devices in the house that consume high levels of
electricity. Also make sure that the backup thermostat is
turned off.
12.9.10 Settings Round circulation
schedule
Round circulation is equipment which an electricity
supplier can fit in order to disconnect, for a short period
of time, equipment which draws high current. The
compressor and electrical output are blocked when
Round circulation is active.
This menu bar is displayed if a "Schedule" has been
defined for the "Round circulation" function.
The "Round circulation" function can also be controlled
remotely by activating the "Input" defined for the
function in the "Installer/Define/Remote Control" menu.
For more information, refer to:
• chapter "Weekly Program" for schedule setting.
• section "Def. Remote Control" of the
"Installer / Define" chapter for defining the remote
control function.
12.9.11 Settings SmartGrid weekly
program
This menu is used to schedule the weekday periods
during which the "SmartGrid" functions should be
active. This schedule is repeated every week.
"SmartGrid" can be used to block a function ("SG
Block") or to achieve a temperature increase during
periods when the energy price is low ("SG Low") or ("SG
Overcapacity").
The "SmartGrid schedule" menu bar is displayed if a
weekly program has been defined for the "SmartGrid A"
function.
For more information, refer to:
• chapter "Weekly Program" for schedule setting.
• chapter "Installer/Define/Remote Control" for
defining SmartGrid.
Menu: "Installer/Settings/SmartGrid schedule".
Menu: "Installer/Settings/Current Sensors".
Menu: "Installer/Settings/Current Sensors". Automatic
configuration of current sensors.
Содержание GSi 600 Series
Страница 26: ...26 CTC GSi 600 CTC GSi 616 CTC GSi 608 GSi 612 qw l min qw l min 6 1 8 Pressure differential diagram hot side ...
Страница 31: ...31 CTC GSi 600 Y60 B2 G2 Y2 G2 B15 B11 6 1 15 Schematic diagram passive cooling alt 1 common cooling heating ...
Страница 33: ...33 CTC GSi 600 B15 B12 B11 B2 G2 G2 Y2 6 1 17 Schematic diagram passive cooling alt 3 ...
Страница 64: ...8 22 HP cooling module schematic diagram 3x400V A5 ...
Страница 65: ...8 23 HP cooling module schematic diagram 1x230V 3x230V A5 ...
Страница 67: ...M GF B25 B26 Y21 B5 G20 B24 B23 B27 B28 G11 G5 B102 B18 ...
Страница 131: ...131 CTC GSi 600 ...
Страница 132: ......
Страница 133: ......
Страница 134: ......
Страница 135: ......
Страница 136: ...Enertech AB P O Box 309 SE 341 26 Ljungby Sweden www ctc se www ctc heating com 162 505 58 1 2020 09 16 ...