CTC GSi 600
Adjusting the heating curve
The method described below can be used to adjust the heating curve correctly.
Adjustment if it is too cold indoors:
• If the outdoor temperature is
lower
than 0 degrees:
Increase the Inclination value by a couple of degrees.
Wait 24 hours to see if any further adjustment is required.
• If the outdoor temperature is
higher
than 0 degrees:
Increase the Adjustment value by a couple of degrees.
Wait 24 hours to see if any further adjustment is required.
Adjustment if it is too warm indoors:
• If the outdoor temperature is lower than 0 degrees:
Decrease the Inclination value by a couple of degrees.
Wait 24 hours to see if any further adjustment is required.
• If the outdoor temperature is higher than 0 degrees:
Decrease the Adjustment value by a couple of degrees.
Wait 24 hours to see if any further adjustment is required.
i
If the values set are too low, this may mean that the desired room temperature
is not being reached. You then need to adjust the heating curve, as necessary,
following the method shown above.
When the basic values have been set more or less correctly, the curve can
be finely adjusted directly using the Room temp. shown on the home menu
screen.
Appropriate Default Values
During installation you can seldom achieve a precise setting for the heating
curve instantly. In this case, the values given below may provide a good
starting point. Radiators with small heat-emission surfaces require a higher
primary flow temperature. You can adjust the gradient (heating curve
gradient) for your heating system under the "Installer / Settings / Radiator
system" menu.
Recommended values are:
Floor
heating
only
Inclination
35
Low temperature system (well insulated houses)
Inclination 40
Normal temperature system (factory setting)
Inclination 50
High temperature system
(older houses, small radiators, poorly insulated)
Inclination 60
Содержание GSi 600 Series
Страница 26: ...26 CTC GSi 600 CTC GSi 616 CTC GSi 608 GSi 612 qw l min qw l min 6 1 8 Pressure differential diagram hot side ...
Страница 31: ...31 CTC GSi 600 Y60 B2 G2 Y2 G2 B15 B11 6 1 15 Schematic diagram passive cooling alt 1 common cooling heating ...
Страница 33: ...33 CTC GSi 600 B15 B12 B11 B2 G2 G2 Y2 6 1 17 Schematic diagram passive cooling alt 3 ...
Страница 64: ...8 22 HP cooling module schematic diagram 3x400V A5 ...
Страница 65: ...8 23 HP cooling module schematic diagram 1x230V 3x230V A5 ...
Страница 67: ...M GF B25 B26 Y21 B5 G20 B24 B23 B27 B28 G11 G5 B102 B18 ...
Страница 131: ...131 CTC GSi 600 ...
Страница 132: ......
Страница 133: ......
Страница 134: ......
Страница 135: ......
Страница 136: ...Enertech AB P O Box 309 SE 341 26 Ljungby Sweden www ctc se www ctc heating com 162 505 58 1 2020 09 16 ...