115
CTC GSi 600
SmartGrid functions are enabled by activating the
SmartGrid inputs in different ways according to the table
on the right.
To enable the SmartGrid function "SG Low Price"
as shown in the example, terminal block K23 must
have power while terminal block K22 should remain
unchanged.
The pool temperature increase that will apply when
"SG Low Price" is activated is set in the "Pool Settings"
menu, as shown in the example.
Alternatively, a weekly program can be set up for
periodic SmartGrid activation. For more information
on setting schedules, refer to the "Weekly Program"
section.
The schedule is set to start at 22:30, weekdays.
K22 (SG A)
K23 (SG B)
Function
Open
Open
Normal
Open
Closed
Low price
Closed
Closed
Overcapacity
Closed
Open
Blocking
Tariff HP
(Off/ K22-K25 /Channel 1A-7B / BMS DI0-7)
This function is used to block the heat pump during
periods when the electricity rate is higher.
In the "Installer / Define/Remote Control" menu:
• specify an "Input" for the remote control function.
In the "Installer / Define/Heat Pump" menu:
• configure the normal mode for the external control
signal (Normally Open (NO)/Normally Closed (NC))
in the "Tariff HP ext. config." row.
In the "Installer/Settings/Heat Pump" menu:
• set "Tariff HP" ("On").
For more information, refer to the "Heating Pump"
section in the "Installer/Settings" chapter.
Menu: "Installer/Define/Heat Pump".
A mode for the external control signal ("Normally Open (NO)" or
"Normally Closed (NC)") is defined for "Tariff HP ext. config.".
HP Noise reduction
(Off/ K22-K25 /Channel 1A-7B / BMS DI0-7)
This function can be used to reduce compressor speed
in order to reduce the noise level.
In the "Installer / Define/Remote Control" menu:
• specify an "Input" for the remote control function.
In the "Installer / Define/Heat Pump" menu:
• configure the normal mode for the external control
signal (Normally Open (NO)/Normally Closed (NC))
in the "Noise reduction ext. config." row.
In the "Installer/Settings/Heat Pump"* menu:
• in the "Ext. Noise reduction rps" row, set the
compressor speed value applicable for remote
control.
For more information, refer to the "Heating Pump"
section in the "Installer/Settings" chapter.
Menu: "Installer/Settings/Heat Pump".
Set the compressor speed value applicable for remote control
in the "Ext. Noise reduction rps" row.
Menu: "Installer/Define/Heat Pump".
A mode for the external control signal ("Normally Open (NO)"
or "Normally Closed (NC)") is defined for "Noise reduction ext.
config.".
Содержание GSi 600 Series
Страница 26: ...26 CTC GSi 600 CTC GSi 616 CTC GSi 608 GSi 612 qw l min qw l min 6 1 8 Pressure differential diagram hot side ...
Страница 31: ...31 CTC GSi 600 Y60 B2 G2 Y2 G2 B15 B11 6 1 15 Schematic diagram passive cooling alt 1 common cooling heating ...
Страница 33: ...33 CTC GSi 600 B15 B12 B11 B2 G2 G2 Y2 6 1 17 Schematic diagram passive cooling alt 3 ...
Страница 64: ...8 22 HP cooling module schematic diagram 3x400V A5 ...
Страница 65: ...8 23 HP cooling module schematic diagram 1x230V 3x230V A5 ...
Страница 67: ...M GF B25 B26 Y21 B5 G20 B24 B23 B27 B28 G11 G5 B102 B18 ...
Страница 131: ...131 CTC GSi 600 ...
Страница 132: ......
Страница 133: ......
Страница 134: ......
Страница 135: ......
Страница 136: ...Enertech AB P O Box 309 SE 341 26 Ljungby Sweden www ctc se www ctc heating com 162 505 58 1 2020 09 16 ...