![CTC Union GSi 600 Series Скачать руководство пользователя страница 109](http://html1.mh-extra.com/html/ctc-union/gsi-600-series/gsi-600-series_installation-and-maintenance-manual_2693362109.webp)
109
CTC GSi 600
12.10.1.1 Setting the remote control function,
example
1. Define an "Input"
First, an input must be assigned to the function or
functions to be controlled remotely. This is done in the
"Installer/Define/Remote Control" menu.
In the example, terminal block K24 is selected as the
input for the "HC1 Heat Mode, Ext." function.
2. Configure the function
(Normally Open (NO)/Normally Closed (NC))
Define a normal mode for the external control signal; NO
or NC. The setting is made for the current heating circuit
in the "Installer/Define/Heating Circuit” menu.
For example, a two-way switch can be connected to the
defined input.
If the button when used generates a control signal on
the input (circuit closes), the circuit shall be defined
as NO. When the circuit closes and the control signal
is generated, the heating mode selected in the "HC1
Heating mode, ext." row is activated in the settings
menu for the heating circuit.
3. Setting the heating mode
In the example, the remote control function "Heating
mode, ext." is set to the "Off" position in the "Heating
mode, ext." row. This setting is made in the "Installer/
Settings/heating circuit" menu.
In this example, the normal heating mode is active
("On").
When input K24 is closed (the multi-button in the
example generates a control signal), the status of
the Heating Mode (normal mode "On"
>
mode "Off")
changes.
Heating remains off until you choose to start the heating
(normal mode "On") by opening terminal block K24 (no
signal on the terminal block).
Open terminal block = Heating mode "On" (in this example).
Closed terminal block = Heating mode "Off" (in this example).
Menu: "Installer / Define /Remote Control".
Remote control function "HC1 Heating mode, ext." is assigned
to terminal block "K24".
Menu: "Installer/Define/Heating Circuit/ Heating Circuit 1". The
normal mode of the remote control signal is defined in the
"HC1 Heating mode ext. config" row.
Menu: "Installer/Settings/Heating Circuit/ Heating Circuit 1"
Remote control mode "Off" becomes active when terminal
block K24 closes.
Содержание GSi 600 Series
Страница 26: ...26 CTC GSi 600 CTC GSi 616 CTC GSi 608 GSi 612 qw l min qw l min 6 1 8 Pressure differential diagram hot side ...
Страница 31: ...31 CTC GSi 600 Y60 B2 G2 Y2 G2 B15 B11 6 1 15 Schematic diagram passive cooling alt 1 common cooling heating ...
Страница 33: ...33 CTC GSi 600 B15 B12 B11 B2 G2 G2 Y2 6 1 17 Schematic diagram passive cooling alt 3 ...
Страница 64: ...8 22 HP cooling module schematic diagram 3x400V A5 ...
Страница 65: ...8 23 HP cooling module schematic diagram 1x230V 3x230V A5 ...
Страница 67: ...M GF B25 B26 Y21 B5 G20 B24 B23 B27 B28 G11 G5 B102 B18 ...
Страница 131: ...131 CTC GSi 600 ...
Страница 132: ......
Страница 133: ......
Страница 134: ......
Страница 135: ......
Страница 136: ...Enertech AB P O Box 309 SE 341 26 Ljungby Sweden www ctc se www ctc heating com 162 505 58 1 2020 09 16 ...