Alarm messages
If a fault occurs with e.g. a sensor, an alarm is triggered. A message appears on the
display with information about the fault.
You reset the alarm by pressing the Reset Alarm button on the display. If several alarms
are triggered, they are displayed one after the other. A persisting fault must first be
rectified before it can be reset. Some alarms are reset automatically if the fault ceases.
Alarm messages
Description
[E010] Compressor type?
This message appears if no information about the compressor type is
available.
[E013] EVO off
This message appears when there is a fault with the expansion valve control.
[E024] Fuse blown
This message appears when the fuse (F1, F2) has been triggered.
[E026] Heat pump
This message appears if the heat pump is in alarm mode.
[E027] Comm. error HP
[E063] Comm. err. relay board
[E056] Comm. err. motor
protection
[E086] Comm. err. expansion
card
This message is displayed when the display card (A1) cannot communicate
with the HP control card (A5).
This message is displayed when the display card (A1) cannot communicate
with the relay card (A2).
This message is displayed when the HP control card (A5) cannot
communicate with the motor protection (A4).
This message is displayed when the display card (A1) cannot communicate
with CTC Solar control/Expansion card (A3).
[E035] High pressure switch
The refrigerant’s high pressure switch has been triggered. Press reset and
check whether the alarm recurs. If the fault recurs, contact your installer.
[E040] Low brine flow
Low brine flow is often caused by air in the collector system, especially
immediately following installation. Collectors which are too long can also be a
cause. Press reset and check whether the alarm recurs. Also check the brine
filter that has been installed.
If the fault recurs, contact your installer.
[E041] Low brine temp.
Incoming brine temperatures from bore hole/ground loop are too low. Press
reset and check whether the alarm recurs. If the fault recurs, contact your
installer to check the dimensions of the cold side.
[E044] Stop, high compr temp
This message appears when the compressor temperature is high.
Press reset and check whether the alarm recurs. If the fault recurs, contact
your installer.
[E045] Stop, low evaporation
This message appears when the evaporation temperature is low.
Press reset and check whether the alarm recurs. If the fault recurs, contact
your installer.
[E046] Stop, high evaporation
This message appears when the evaporation temperature is high.
Press reset and check whether the alarm recurs. If the fault recurs, contact
your installer.
Содержание GSi 600 Series
Страница 26: ...26 CTC GSi 600 CTC GSi 616 CTC GSi 608 GSi 612 qw l min qw l min 6 1 8 Pressure differential diagram hot side ...
Страница 31: ...31 CTC GSi 600 Y60 B2 G2 Y2 G2 B15 B11 6 1 15 Schematic diagram passive cooling alt 1 common cooling heating ...
Страница 33: ...33 CTC GSi 600 B15 B12 B11 B2 G2 G2 Y2 6 1 17 Schematic diagram passive cooling alt 3 ...
Страница 64: ...8 22 HP cooling module schematic diagram 3x400V A5 ...
Страница 65: ...8 23 HP cooling module schematic diagram 1x230V 3x230V A5 ...
Страница 67: ...M GF B25 B26 Y21 B5 G20 B24 B23 B27 B28 G11 G5 B102 B18 ...
Страница 131: ...131 CTC GSi 600 ...
Страница 132: ......
Страница 133: ......
Страница 134: ......
Страница 135: ......
Страница 136: ...Enertech AB P O Box 309 SE 341 26 Ljungby Sweden www ctc se www ctc heating com 162 505 58 1 2020 09 16 ...