6.3.1 User
Access
Rights
The following table is a list of the available user rights, where to find the menu item(s) applicable to
the user right and a description of what it applies to. Certain menu items may not be available on
your chamber depending upon available options.
User Right
Menu Location
Description
Setpoint Entry
View/Main, Overview
applies to loop controls when not running an
automatic ramp/soak program (does not apply to
loop/monitor alarms)
Events
View/Overview,Main; Manual Operation
applies to enable or disable system events
Reset Pumpdown
View/Alarm; Pumpdown button
allows manual reset of pumpdown
Tuning System/Settings/View/Tuning
allows
activation of loop automatic tune function and
manual adjustment of PID parameters
Program Operation
see description
applies to Start, Hold, Stop, Off actions; does not
affect digital Inputs configured for same action
Recovery
System/Settings/Setup/Recovery
logic when running an automated ramp/soak program
when power lost & recovery: Off, Hold, Continue,
Restart or Resume
Reset Alarms
View/Alarm; Reset Button
View/Status; Reset Button
allows user to reset and silence audible alarm
Clear Alarms
View/Alarm; Clear button
allows user to clear alarm list
Trend Setup
View/Trend; Setup button
configure plot channels, scale & time for trends
Data
Data/Logging
applies to all data logging actions & settings; does not
affect digital input functions
Annotation Data/Logging/View/Annotation
access
to add operator messages to active log file
Signature
Data/ Logging /View/Signature
access to add digital signature to active historical data
file
Open
see description
alarm, automatic program, audit & data files
Save
see description
program “save” and “save as”; note files may be
copied from system with USB file transfer utilities
Delete
see description
data files & automatic programs; note files may be
deleted with File Utilities
Program Edit
Program/Entry
no data entry or access to Events or Step SP/Time
fields or G-Soak Limits, AutoStart; can't
insert/delete/copy/paste step.
USB
Data/Logging/Utilities/USB
allows USB memory stick to copy/delete data, alarm,
program & audit trail files & to import programs
FTP/WAN Data/Logging/Utilities/FTP/WAN
configure FTP client settings, start manual backup
Communications System/Settings/Comms/User
configure web page, Modbus address & VNC settings
Barcode System/Settings/Comms/Barcode
applies to all barcode reader settings
Defrost System/Settings/View/Defrost
applies
to defrost mode, interval and set point
Product Control
System/Settings/Setup/Product
access to configure product control settings
Condensate Control
System/Settings/View/Condensation
access to configure condensation control settings
Monitor Names
System/Settings/Offline/Settings/
Calibrate/Offset
access to change optional monitor input names
Setpoint Limits
System/Settings/Setup/Setpoint Limits
applies to loop controls (does not apply to
loop/monitor alarms)
Adjust Alarms
System/Settings/Setup/Alarm
applies to all loop and monitor point alarms
Event Names
System/Settings/Setup/Event Names
configure customer event names (seen in Overview &
program step Events)
Email Settings
System/Settings/Email/Settings
configure email settings and addresses
Email Message
System/Settings/Email/Message
access to compose & send email message
Offline System/Settings/Offline/Settings
access to Off-Line menu system: Service items &
Options, Units, set Clock, Display settings, Language,
Exit Application, monitor Offset, Configuration,
Analog Input & Output Setup, Digital Input & Output
Setup and Special Settings
Service System/Settings/Offline/Settings/
applies to counter set point entry and clearing