MFR_CLEAR_FAULT_COUNT
[F5h]
Send
It resets the number of times stopping by the protective function.
Note1: After command transmission, do not shutdown the input voltage for more than 1 second.
Display format
: -
Initial setting
: -
Range of setting and reading
: -
MFR_VIN_OV_FAULT_COUNT
[F8h]
Read
It reads the number of times stopping by the input overvoltage protection feature.
Note1: For clear the count, use MFR_CLEAR_FAULT_COUNT [ F5h ].
Note2: For saving count, don't block the input voltage, between 100ms output voltage is stopped.
Display format
: Linear(Count)
Initial setting
: 0 [ times ]
Range of setting and reading
: 0 - 255 [ times ]
MFR_VIN_UV_FAULT_COUNT
[F9h]
Read
It reads the number of times stopping by low input voltage protection feature.
Note1: For clear the count, use MFR_CLEAR_FAULT_COUNT [ F5h ].
Note2: For saving count, don't block the input voltage, between 100ms output voltage is stopped.
Display format
: Linear(Count)
Initial setting
: 0 [ times ]
Range of setting and reading
: 0 - 255 [ times ]
#
bit
value
Overview
1
bit7-0
00000000
It reads the number of times stopping by the input undervoltage fault.
1
It reads the number of times stopping by the input overvoltage fault.
#
bit
value
Overview
bit7-0
00000000
Applications manual
For CHS300/400/500-
I
series
- 55 -