OT_WARN_LIMIT
[51h]
R/W Word
Sets the over-temperature warning threshold.
When the temperature detecting-element temperature exceeds this threshold, it outputs an alarm.
Display format
: Linear(Temp)
Initial setting,
: 129 [
̊
C ] , -45 - 139 [
̊
C ] (CHS3004810-I)
Range of setting and reading
: 129 [
̊
C ] , -45 - 139 [
̊
C ] (CHS3004812-I)
: 129 [
̊
C ] , -45 - 139 [
̊
C ] (CHS4004812-I)
: 116 [
̊
C ] , -45 - 126 [
̊
C ] (CHS5004812-I)
UT_WARN_LIMIT
[52h]
R/W Word
Sets the under-temperature warning threshold.
When the temperature detecting-element temperature falls below this threshold, it outputs an alarm.
Display format
: Linear(Temp)
Initial setting
: -40 [
̊
C]
Range of setting and reading
: -45 - 20 [
̊
C]
UT_FAULT_LIMIT
[53h]
R/W Word
Sets the undertemperature fault threshold.
When the temperature detecting-element temperature is below this threshold,
it does the operation to specify at UT_FAULT_RESPONSE [ 54h ].
Display format
: Linear(Temp)
Initial setting
: -45 [
̊
C]
Range of setting and reading
: -45 - 20 [
̊
C]
Applications manual
For CHS300/400/500-
I
series
- 39 -