IOUT_OC_WARN_LIMIT
[4Ah]
R/W Word
Sets the current value that will trigger an overcurrent warning condition
if the output current exceeds this set value.
Display format
: Linear(Iout)
Initial setting,
: 33.0 [ A ] , 10.00 - 36.00 [ A ] (CHS3004810-I)
Range of setting and reading
: 27.5 [ A ] , 10.00 - 30.00 [ A ] (CHS3004812-I)
: 36.3 [ A ] , 10.00 - 39.75 [ A ] (CHS4004812-I)
: 48.3 [ A ] , 10.00 - 50.50 [ A ] (CHS5004812-I)
OT_FAULT_LIMIT
[4Fh]
R/W Word
Sets the over-temperature fault threshold.
When temperature exceeds this value, setting of OT_FAULT_RESPONSE [ 50h ] is activated.
Display format
: Linear(Temp)
Initial setting,
: 139 [
̊
C ] , -45 - 139 [
̊
C ] (CHS3004810-I)
Range of setting and reading
: 139 [
̊
C ] , -45 - 139 [
̊
C ] (CHS3004812-I)
: 139 [
̊
C ] , -45 - 139 [
̊
C ] (CHS4004812-I)
: 126 [
̊
C ] , -45 - 126 [
̊
C ] (CHS5004812-I)
Applications manual
For CHS300/400/500-
I
series
- 37 -