VOUT_MARGIN_HIGH
[25h]
R/W Word (only CHS400/500-I)
Sets the value of the output voltage during the margin high operation state.
To change the operation to output margin high, please refer to the operation command.
Display format
: Linear(Vo)
Initial setting
: 13.2 [ V ]
Range of setting and reading
: 10.8 - 13.2 [ V ]
*1
*1: The value added VOUT_TRIM [ 22h ] becomes the upper limit.
Also, the value which exceeds VOUT_MAX [ 24h ] can not be set.
VOUT_MARGIN_LOW
[26h]
R/W Word (only CHS400/500-I)
Sets the value of the output voltage during the margin low operation state.
To change the operation to output margin low, please refer to the OPERATION [ 01h ] command.
Display format
: Linear(Vo)
Initial setting
: 10.8 [ V ]
Range of setting and reading
: 8.1 - 13.2 [ V ]
*1
*1: The value added VOUT_TRIM [ 22h ] becomes the upper limit.
Also, the value which exceeds VOUT_MAX [ 24h ] can not be set.
Applications manual
For CHS300/400/500-
I
series
- 32 -