STATUS_VOUT
[7Ah]
R/W Byte
This command returns the output voltage related status.
Display format
: -
Initial setting
: 00 h
Range of setting and reading
: -
*1: Bit6 of STATUS_CML [ 7Eh ] sets at 1.
STATUS_IOUT
[7Bh]
R/W Byte
This command returns the output current related status.
Display format
: -
Initial setting
: 00 h
Range of setting and reading
: -
6
7
8
#
1
2
3
4
5
3
4
8
6
7
5
#
1
2
bit
Value
Overview
bit7
0
The output voltage sets above VOUT_OV_FAULT_LIMIT [ 40h ].
bit6
0
The output voltage sets above VOUT_OV_WARN_LIMIT [ 42h ].
bit5
0
The output voltage sets below VOUT_UV_WARN_LIMIT [ 43h ].
bit4
0
The output voltage sets below VOUT_UV_FAULT_LIMIT [ 44h ].
bit3
0
The output voltage set value sets above VOUT_MAX [ 24h ]. *1
( not supported )
bit2
0
Start-up time sets above TON_MAX_FAULT_LIMIT [ 62h ].
bit1
0
The stop time sets above TOFF_MAX_WARN_LIMIT.
( not supported )
bit0
0
-
bit
Value
Overview
bit7
0
The output current sets above IOUT_OC_FAULT_LIMIT.
( not supported )
bit6
0
The output voltage sets below IOUT_OC_UV_LIMIT in case of the over-current
. ( not supported )
bit5
0
The output current sets above IOUT_OC_WARN_LIMIT [ 4Ah ].
bit4
0
The output current sets below IOUT_UC_FAULT_LIMIT.
( not supported )
bit3
0
-
bit2
0
It sets when working by the constant power mode to set in POUT_MAX. ( not supported )
bit1
0
The output power sets above POUT_OP_FAULT_LIMIT.
( not supported )
bit0
0
The output power sets above POUT_OP_WARN_LIMIT.
( not supported )