MFR_C2_LOGIC
[E1h]
R/W Byte
It does the setting of remote control ( secondary side ) and a reading.
Display format
: -
Initial setting
: 00 h
Range of setting and reading
: -
MFR_PGOOD_POLARITY
[E2h]
R/W Byte
It does the setting of the polarity of the Power_Good signal and a reading.
Display format
: -
Initial setting
: 00 h
Range of setting and reading
: -
MFR_OT_RESTART_LIMIT
[E3h]
R/W Word
It does the setting of the return threshold of the overtemperature protection and a reading.
In the case of automatic restart mode, it does an automatic-restart, when the temperature of the
detecting-element is below this threshold.
Display format
: Linear(Temp)
Initial setting
: 90 [
℃
]
Range of setting and reading
: -45 - 90 [
℃
]
Overview
spare
Power_Good signal is negative logic (when output voltage is normal: Low)
Power_Good signal is positive (when output volte is normal: High)
#
1
2
bit
value
bit7-1
3
4
5
#
1
2
3
2
1
0
bit
7
6
5
4
3
R/W
0
Initial value
0
0
0
0
0
0
0
R/W
R/W
bit
Value
Overview
Access
R/W
R/W
R/W
R/W
bit7-2
000000
Spare
bit1
0
The remote control ( secondary side) feature is invalid.
1
The remote control ( secondary side) feature is valid.
bit0
0
The remote control ( secondary side) feature is negative-logic. (C2 input < 0.8V)
1
The remote control ( secondary side) feature is positive-logic. (C2 input > 2.1V)
bit
7
6
5
4
0
Initial value
0
0
0
0
0
0
Access
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0000000
0
1
0
0
3
2
1
R/W
bit0
Applications manual