MFR_SERIAL [9Eh]
Block Read
This command returns a string of 7 numbers that provides a serial number.
Display format
: ASCII code (7 letter)
Initial setting
: -
Range of setting and reading
: -
Display example
:
"9527653"
MFR_C2_ARA_CONFIG
[E0h]
R/W Byte
It does the setting of C2 terminal feature and SMBAlert feature and a reading.
By the setting of bit4, the ARA change existence or non-existence at the time of SMBAlert can be chosen.
Also, by the setting of bit3-0, the C2 terminal can be chosen in the remote control
( secondary side) or Power_Good.
Display format
: -
Initial setting
: 01 h
Range of setting and reading
: -
6
bit
#
3
2
4
1
7
6
5
4
3
2
1
0
Initial value
0
0
0
0
0
0
0
1
Access
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0010
It uses C2 terminal as the remote control ( secondary side ) terminal.
R/W
bit
Value
Overview
bit7-5
000
Spare
It uses C2 terminal as the Power_Good output terminal.
5
bit4
0
At the time of SMBAlert, it replies to both of ARA and the setting address.
1
It uses ARA and at the time of SMBAlert, it replies only to ARA.
bit3-0
0001
0101
It uses C2 terminal as the Power_Good_IOG output terminal.
Applications manual
For CHS300/400/500-
I
series