POWER_GOOD_ON
[5Eh]
R/W Word
This command sets the voltage threshold for Power-Good indication.
Power-Good asserts when the output voltage exceeds POWER_GOOD_ON, if the C2 terminal
is used as Power-Good.
Display format
: Linear(Vo)
Initial setting,
:
0
9.0 [ V ] , 0.0 - 12.5 [ V ] (CHS3004810-I)
Range of setting and reading
: 10.8 [ V ] , 0.0 - 15.0 [ V ] (CHS3004812-I)
*1
: 10.8 [ V ] , 0.0 - 15.0 [ V ] (CHS4004812-I)
: 10.8 [ V ] , 0.0 - 15.0 [ V ] (CHS5004812-I)
*1:
It can not be set to a value lower than POWER_GOOD_OFF [ 5Fh ]
POWER_GOOD_OFF
[5Fh]
R/W Word
This command sets the voltage threshold for de-assertion of Power-Good indication.
Power-Good de-asserts when the output voltage is less than POWER_GOOD_OFF, if the C2 terminal
is used as Power-Good.
Display format
: Linear(Vo)
Initial setting,
:
0
8.0 [ V ] , 0.0 - 12.5 [ V ] (CHS3004810-I)
Range of setting and reading
: 10.8 [ V ] , 0.0 - 15.0 [ V ] (CHS3004812-I)
*1
: 10.8 [ V ] , 0.0 - 15.0 [ V ] (CHS4004812-I)
: 10.8 [ V ] , 0.0 - 15.0 [ V ] (CHS5004812-I)
*1:
It can not be set to a value higher than POWER_GOOD_ON [ 5Eh ]
TON_DELAY
[60h]
R/W Word
This command sets the delay time from ENABLE to start of the rise of the output voltage.
When setting more shortly than the original delay time of the power, it is fixed at the delay time.
Display format
: Linear(Time)
Initial setting
: 0 [ ms ]
Range of setting and reading
: 0 - 500 [ ms ]
*1
*1:
The set value can be set by the 50 ms.
TON_RISE
[61h]
R/W Word (only CHS400-I)
This command sets the rise time of the output voltage after ENABLE and TON_DELAY.
When setting more shortly than the original start time of the power, it is fixed at the start time.
Display format
: Linear(Time)
Initial setting
: 0 [ ms ]
Range of setting and reading
: 0 - 500 [ ms ]
*1
*1:
The set value can be set by the 50 ms.
Applications manual
For CHS300/400/500-
I
series
- 43 -