VIN_ON
[35h]
R/W Word
Sets the input voltage at which the module should start power conversion.
Display format
: Linear(Vin)
Initial setting
: 34.5 [ V ]
Range of setting and reading
: 32 - 46 [ V ]
*1
*1: It isn't possible to set to the value below [ 36h ].
VIN_OFF
[36h]
R/W Word
Sets the threshold of input voltage below which the output voltage is always disabled.
Display format
: Linear(Vin)
Initial setting
: 32 [ V ]
Range of setting and reading
: 32 - 46 [ V ]
*1
*1: The value which added VOUT_TRIM [ 22 h ] becomes the upper limit.
It isn't possible to set to the value which exceeds VIN_ON [ 35h ].
VOUT_OV_FAULT_LIMIT
[40h]
R/W Byte
Sets the output overvoltage fault threshold.
Set higher than VOUT_COMMAND [ 21h ].
When the output voltage exceeds this threshold, it does the operation to specify at
VOUT_OV_FAULT_RESPONSE [ 41h ].
Display format
: Linear(Vo)
Initial setting,
: 12.5 [ V ] , 6.6 - 12.5 [ V ] (CHS3004810-I)
Range of setting and reading
: 15.0 [ V ] , 8.1 - 15.0 [ V ] (CHS3004812-I)
: 15.0 [ V ] , 8.1 - 15.0 [ V ] (CHS4004812-I)
: 15.0 [ V ] , 8.1 - 15.0 [ V ] (CHS5004812-I)
Applications manual
For CHS300/400/500-
I
series
- 33 -