Table 9-1 Supported command and setting (sequel)
MFR_SERIAL
9E h
-
-
-
59
Read
Block
-
-
-
-
58
MFR_LOCATION
9C h
Read
Block
-
57
MFR_REVISION
9B h
Read
Block
-
56
MFR_MODEL
9A h
Read
Block
-
63
MFR_OT_RESTART_LIMIT
E3 h
R/W
Word
Linear(Temp)
90
[
℃
]
00 h
-
62
MFR_PGOOD_POLARITY
E2 h
R/W
Byte
-
00 h
61
MFR_C2_LOGIC
E1 h
R/W
Byte
-
60
MFR_C2_ARA_CONFIG
E0 h
R/W
Byte
-
01 h
-
-
-
[W]
55
PMBUS_REVISION
98 h
Read
Byte
[
℃
]
-
22 h
54
READ_PIN
97 h
Read
Word
Linear(Pin)
-
[A]
53
READ_TEMPERATURE_1
8D h
Read
Word
Linear(Temp)
-
52
READ_IOUT
8C h
Read
Word
Linear(Iout)
51
READ_VOUT
8B h
Read
Word
Linear(Vo)
-
[V]
-
50
READ_VIN
88 h
Read
Word
Linear(Vin)
-
[V]
00 h
-
49
STATUS_CML
7E h
R/W
Byte
-
00 h
48
STATUS_TEMPERATURE
7D h
R/W
Byte
-
47
STATUS_INPUT
7C h
R/W
Byte
-
00 h
-
-
46
STATUS_IOUT
7B h
R/W
Byte
-
00 h
-
00 h
-
45
STATUS_VOUT
7A h
R/W
Byte
-
00 h
44
STATUS_WORD
79 h
R/W
Word
-
#
PMBus command
Code
(*1)
Type
(*2)
Data
length
(*3)
Data format
Initial
setting
Unit
Note
-
43
STATUS_BYTE
78 h
R/W
Byte
-
00 h
-
30
[ms]
42
TON_MAX_FAULT_RESPONSE
63 h
R/W
Byte
-
00 h
41
TON_MAX_FAULT_LIMIT
62 h
R/W
Word
Linear(Time)
40
TON_RISE
61 h
R/W
Word
Linear(Time)
0
[ms]
only CHS400-I
[V]
39
TON_DELAY
60 h
R/W
Word
Linear(Time)
0
[ms]
*4
[V]
38
POWER_GOOD_OFF
5F h
R/W
Word
Linear(Vo)
*4
37
POWER_GOOD_ON
5E h
R/W
Word
Linear(Vo)
36
VIN_UV_FAULT_RESPONSE
5A h
R/W
Byte
-
C0 h
-
[V]
35
VIN_UV_FAULT_LIMIT
59 h
R/W
Word
Linear(Vin)
32
[V]
100
[V]
34
VIN_UV_WARN_LIMIT
58 h
R/W
Word
Linear(Vin)
32
33
VIN_OV_WARN_LIMIT
57 h
R/W
Word
Linear(Vin)
32
VIN_OV_FAULT_RESPONSE
56 h
R/W
Byte
-
C0 h
-
-
31
VIN_OV_FAULT_LIMIT
55 h
R/W
Word
Linear(Vin)
100
[V]
-45
[
℃
]
30
UT_FAULT_RESPONSE
54 h
R/W
Byte
-
00 h
29
UT_FAULT_LIMIT
53 h
R/W
Word
Linear(Temp)
28
UT_WARN_LIMIT
52 h
R/W
Word
Linear(Temp)
-40
[
℃
]
-
27
OT_WARN_LIMIT
51 h
R/W
Word
Linear(Temp)
129
[
℃
]
26
OT_FAULT_RESPONSE
50 h
R/W
Byte
-
C0h
-
-
-
Applications manual