2.3.3: Digital Input
Three Formats
In position mode, the drive can accept position commands via two digital inputs, using one of these
signal formats: pulse and direction, count up/count down, and quadrature.
In all three formats, the drive can be configured to invert the command.
Pulse Smoothing
In position mode, the drive’s trajectory generator ensures smooth motion even when the command
source cannot control acceleration and deceleration rates.
When using digital or analog command inputs, the trajectory generator can be disabled by setting
the Max Accel limit to zero. (Note that when using CAN, EtherCAT, ASCII serial, or CVM Control
Program, setting Max Accel to zero prevents motion.)
Pulse and Direction Format
In pulse and direction format, one input takes a series of pulses as motion step commands, and
another input takes a high or low signal as a direction command, as shown below.
The drive can be set to increment position on the rising or falling edge of the signal. Stepping
resolution can be programmed for electronic gearing.
Pulse Input
Velocity
Command
Direction Input
Содержание XEL-230-18
Страница 1: ...123123 P N 16 01344 Revision 06 August 30 2019 Xenus Plus User Guide...
Страница 2: ...Xenus Plus User Guide 16 01344 Rev 06 This page for notes...
Страница 9: ...Xenus Plus User Guide 16 01344 Rev 06 Copley Controls 9 This page for notes...
Страница 18: ...Xenus Plus User Guide 16 01344 Rev 06 Copley Controls 18...
Страница 82: ...Xenus Plus User Guide 16 01344 Rev 06 Copley Controls 82 3 25 3 XE2 XP2 XM2 non N models 800 1819 Dimensions...
Страница 116: ...Xenus Plus User Guide 16 01344 Rev 06 Copley Controls 116 Optically Isolated Programmable Outputs Wiring Diagram...
Страница 120: ...Xenus Plus User Guide 16 01344 Rev 06 Copley Controls 120 Analog Input Wiring Diagram Multi Mode Port Interface Diagram...