Xenus Plus User Guide
16-01344 Rev 06
Copley Controls
69
3.9: Digital Inputs
XEL/XPL/XML
Channels
15 (IN1~IN15)
IN1~IN2, IN15
IN3~IN6
IN7~IN14
Type
Schmitt trigger w/ RC filter,
24Vdc max
Non-isolated line receiver w/
RC filter, programmable as 4
single-ended or 2 differential
Single-ended
Opto-isolated, bi-polar, 2
groups of 4 with common for
each group
Input Voltage
Range
0 Vdc-24 Vdc
0-12Vdc
±15 - 30 Vdc
Logic Low Input
Voltage
≤ +1.13 Vdc
≤ +2.3 Vdc
N/A
Logic High Input
Voltage
≥ +3.15 Vdc
≥ +2.7 Vdc
N/A
Scan Time
250
s
250
s
250
s
Debounce
Type
Time
Digital
Programmable 0 - 10,000 ms
Digital
Programmable 0 - 10,000 ms
Digital
Programmable 0 - 10,000 ms
Function
IN1 enable
IN2~IN15 programmable
Note: Inputs 3&4 and 5&6 can be programmed to function as differential pairs as digital
command inputs.
XE2/XP2/XM2/800-1818/800-1819/800-1887
Channels
XE2/XP2/XM2/800-1818: 22 (IN1~IN22), 800-1819/800-1887: 20 (IN1~IN20)
IN1,11,21~22
IN2~5,12-15
IN6~9,16~19
IN10,20
Type
Schmitt trigger w/ RC
filter, 24Vdc max
Non-isolated line
receiver w/ RC filter,
programmable as 4
single-ended or 2
differential Single-
ended
Opto-isolated, bi-
polar, 2 groups of 4
with common for each
group
Motor overtemp
signals on feedback
connectors
Input Voltage
Range
0 Vdc-24 Vdc
0-12Vdc
±15 - 30 Vdc
0 Vdc-24 Vdc
Logic Low Input
Voltage
≤ +1.13 Vdc
≤ +2.3 Vdc
<= +6 Vdc
≤ +1.13 Vdc
Logic High Input
Voltage
≥ +3.15 Vdc
≥ +2.7 Vdc
>= +10 Vdc
≥ +3.15 Vdc
Scan Time
250
s
Debounce
Type
Time
Digital
Programmable 0 -
10,000 ms
Digital
Programmable 0 -
10,000 ms
Digital
Programmable 0 -
10,000 ms
Digital
Programmable 0 -
10,000 ms
Function
All programmable
Note: 800-1819 and 800-1887 do not utilize IN21-22 and dedicate IN16-19 to optical limit
switches of motors.
Содержание XEL-230-18
Страница 1: ...123123 P N 16 01344 Revision 06 August 30 2019 Xenus Plus User Guide...
Страница 2: ...Xenus Plus User Guide 16 01344 Rev 06 This page for notes...
Страница 9: ...Xenus Plus User Guide 16 01344 Rev 06 Copley Controls 9 This page for notes...
Страница 18: ...Xenus Plus User Guide 16 01344 Rev 06 Copley Controls 18...
Страница 82: ...Xenus Plus User Guide 16 01344 Rev 06 Copley Controls 82 3 25 3 XE2 XP2 XM2 non N models 800 1819 Dimensions...
Страница 116: ...Xenus Plus User Guide 16 01344 Rev 06 Copley Controls 116 Optically Isolated Programmable Outputs Wiring Diagram...
Страница 120: ...Xenus Plus User Guide 16 01344 Rev 06 Copley Controls 120 Analog Input Wiring Diagram Multi Mode Port Interface Diagram...