…Pin Description, continued:
20
+5 Vdc
+5 Vdc output.
Total load current on J8-20, J10-6, and J10-17 not to exceed 400 mA.
21
Multi-Mode Port /X
Programmable differential input/output port.
See Mode Dependent Dedicated Inputs (below).
22
Multi-Mode Port X
23
Multi-Mode Port /B
24
Multi-Mode Port B
25
Multi-Mode Port /A
26
Multi-Mode Port A
Mode-Dependent Dedicated Inputs
These inputs are dedicated to specific functions, depending on operating mode.
Mode
Selected Command Source
Function
Digital Input
Single Ended
Digital Input
Differential
Multi-Mode
Port
Current & Velocity
PWM 50%
IN 5
IN3(+) & IN4(-)
A & /A
PWM Input
Current & Velocity
PWM 100%
IN 5
IN3(+) & IN4(-)
A & /A
PWM Input
IN 6
IN5(+) & IN6(-)
B & /B
Direction Input
Position
Pulse & Direction
IN 5
IN3(+) & IN4(-)
A & /A
Pulse Input
IN 6
IN5(+) & IN6(-)
B & /B
Direction Input
Position
Up/Down
IN 5
IN3(+) & IN4(-)
A & /A
Count Up
IN 6
IN5(+) & IN6(-)
B & /B
Count Down
Position
Quadrature
IN 5
IN3(+) & IN4(-)
A & /A
Channel A
IN 6
IN5(+) & IN6(-)
B & /B
Channel B
Digital Inputs (IN1~IN6) Wiring Diagram
Содержание XEL-230-18
Страница 1: ...123123 P N 16 01344 Revision 06 August 30 2019 Xenus Plus User Guide...
Страница 2: ...Xenus Plus User Guide 16 01344 Rev 06 This page for notes...
Страница 9: ...Xenus Plus User Guide 16 01344 Rev 06 Copley Controls 9 This page for notes...
Страница 18: ...Xenus Plus User Guide 16 01344 Rev 06 Copley Controls 18...
Страница 82: ...Xenus Plus User Guide 16 01344 Rev 06 Copley Controls 82 3 25 3 XE2 XP2 XM2 non N models 800 1819 Dimensions...
Страница 116: ...Xenus Plus User Guide 16 01344 Rev 06 Copley Controls 116 Optically Isolated Programmable Outputs Wiring Diagram...
Страница 120: ...Xenus Plus User Guide 16 01344 Rev 06 Copley Controls 120 Analog Input Wiring Diagram Multi Mode Port Interface Diagram...