3.14: Analog Encoder Inputs
XEL/XPL/XML
Channels
2
Type
Differential, non-isolated
Signals
Sin(+), Sin(-), Cos(+), Cos(-)
Nominal Voltage
1 Vpk-pk
Maximum Voltage
Differential
Input to Ground
±0.6 Vdc
0 to +3.5 Vdc
Differential Input Impedance
121
Bandwidth
230 kHz
Interpolation
1 to 1024, programmable
Function
Incremental or analog encoder or resolver required for sinusoidal
commutation and position or velocity modes of operation.
XE2/XP2/XM2/800-1818
Channels
4
Type
Differential, non-isolated
Signals
Sin(+), Sin(-), Cos(+), Cos(-) for each axis.
Nominal Voltage
1 Vpk-pk
Maximum Voltage
Differential
Input to Ground
±0.6 Vdc
0 to +3.5 Vdc
Differential Input Impedance
121
Bandwidth
230 kHz
Interpolation
1 to 1024, programmable
Function
Incremental or analog encoder or resolver required for sinusoidal
commutation and position or velocity modes of operation.
NOTE: There is no Analog Encoder feedback on 800-1819 and 800-1887 drives.
Содержание XEL-230-18
Страница 1: ...123123 P N 16 01344 Revision 06 August 30 2019 Xenus Plus User Guide...
Страница 2: ...Xenus Plus User Guide 16 01344 Rev 06 This page for notes...
Страница 9: ...Xenus Plus User Guide 16 01344 Rev 06 Copley Controls 9 This page for notes...
Страница 18: ...Xenus Plus User Guide 16 01344 Rev 06 Copley Controls 18...
Страница 82: ...Xenus Plus User Guide 16 01344 Rev 06 Copley Controls 82 3 25 3 XE2 XP2 XM2 non N models 800 1819 Dimensions...
Страница 116: ...Xenus Plus User Guide 16 01344 Rev 06 Copley Controls 116 Optically Isolated Programmable Outputs Wiring Diagram...
Страница 120: ...Xenus Plus User Guide 16 01344 Rev 06 Copley Controls 120 Analog Input Wiring Diagram Multi Mode Port Interface Diagram...