XPL J6 NET Indicator: CANopen RUN and ERR States
The color/blink codes of the NET indicator on J6 comply with CAN Indicator Specification
CiA 303-3 as shown on the following pages. Green is the RUN state and red is the ERR state. Note
that green and red codes alternate, each indicating a different set of conditions.
The red/green ACT/ERR LEDs indicate the status of the physical layer.
The green ACT LED indicates physical connection and activity. No connection or network errors
show the red ERR LED. In addition, these are turned off when the CAN node ID selector
(CAN ADDR) is set to 0. A setting of 0, which is invalid, shuts down most operations on the
CAN interface, and the LEDs are shut off to indicate this status.