Xenus Plus User Guide
16-01344 Rev 06
Copley Controls
80
3.24: Mechanical and Environmental
XEL/XPL/XML
Size
7.92 in (201,2 mm) X 5.51 in (139,9 mm) X 2.31 in (58,7 mm)
Weight
Driver without Heat Sink
Low profile (
–HL) Heat Sink
Standard (
–HS) Heat Sink
3.0 lb (1.36 kg)
Add 1.86 lb (0.84 kg)
Add 3.1 lb (1.40 kg)
Ambient Temperature
Storage
Operating
-40 to +85°C
0 to +45°C
Humidity
0% to 95%, non-condensing
Contaminants
Pollution degree 2
Environment
IEC60068-2: 2007
Cover Material
Meets UL Spec 94 V-0 Flammability Rating
Cooling
Heat sink and/or forced air cooling required for continuous power output
XE2/XP2/XM2/800-1818/800-1819/800-1887
Size
XE2/XP2/XM2
(non “-N” models)/800-1819:
-
9.24 in (234,7 mm) X 5.42 in (137,6 mm) X 3.59 in (91,1 mm)
XE2/XP2/XM2 (“-N” models)/800-1818/800-1887:
-
9.24 in (234,7 mm) X 5.57 in (141,6 mm) X 2.31 in (58,7 mm)
Weight
XE2/XP2/XM2 (non “-N” models)/800-1819: 4.19 lb (1.90 kg)
XE2/XP2/XM2 (“-N” models)/800-1818/800-1887: 3.13 lb (1.42 kg)
Ambient Temperature
Storage
Operating
-40 to +85°C
0 to +40°C
Altitude
≤ 2000 m per IEC 60068-2-13:1983 if an SPD is used to establish an OVC II
environment
≤ 4000 m per IEC 60068-2-13:1983 if a mains isolation transformer is used to establish
an OVC II environment
Humidity
0% to 95%, non-condensing
Contaminants
Pollution degree 2
Ingress Protection
IP20
Vibration
2
g
peak, 10~500 Hz (sine), IEC60068-2-6
Shock
10
g
, 10 ms, half-sine pulse, IEC60068-2-27
Environment
IEC60068-2: 2007
Cooling
XE2/XP2/XM2 (non “-N” models)/800-1819:
-
Integrated heatsink and cooling fan provide required cooling
XE2/XP2/XM2 (“-N” models)/800-1818/800-1887:
-
Dependent on mounting orientation and ambient airflow
Содержание XEL-230-18
Страница 1: ...123123 P N 16 01344 Revision 06 August 30 2019 Xenus Plus User Guide...
Страница 2: ...Xenus Plus User Guide 16 01344 Rev 06 This page for notes...
Страница 9: ...Xenus Plus User Guide 16 01344 Rev 06 Copley Controls 9 This page for notes...
Страница 18: ...Xenus Plus User Guide 16 01344 Rev 06 Copley Controls 18...
Страница 82: ...Xenus Plus User Guide 16 01344 Rev 06 Copley Controls 82 3 25 3 XE2 XP2 XM2 non N models 800 1819 Dimensions...
Страница 116: ...Xenus Plus User Guide 16 01344 Rev 06 Copley Controls 116 Optically Isolated Programmable Outputs Wiring Diagram...
Страница 120: ...Xenus Plus User Guide 16 01344 Rev 06 Copley Controls 120 Analog Input Wiring Diagram Multi Mode Port Interface Diagram...