2.5.5: XML J6: Drive and MACRO Network Status Indicators
XML J6 STAT Indicator: Drive Status
Indicator color/blink codes are described below.
Color/Blink Code
Meaning
Not illuminated
No +24 Vdc power to drive.
Steady green
Drive is enabled and operational.
Slow-blinking green
Drive is disabled. No faults or warnings are active.
Fast-blinking green
A limit switch is active. The drive is enabled.
Green flash twice
followed by a pause
MTO is active, One or both MTO inputs are de-energized. The drive is hardware &
software enabled but the PWM outputs cannot produce current in the motor when
MTO is active.
Steady red
A non-latched fault has occurred.
Blinking red
A latched fault has occurred.
XML J6 NET Indicator: MACRO Network Status
NET
Description
Off
MACRO network has not been detected.
Blinking green
MACRO network detected and has disabled drive.
Green
MACRO network detected and is trying to enable drive. This condition can occur
while the AMP LED shows any of its valid color combinations.
Steady red
MACRO network errors have been detected.
Содержание XEL-230-18
Страница 1: ...123123 P N 16 01344 Revision 06 August 30 2019 Xenus Plus User Guide...
Страница 2: ...Xenus Plus User Guide 16 01344 Rev 06 This page for notes...
Страница 9: ...Xenus Plus User Guide 16 01344 Rev 06 Copley Controls 9 This page for notes...
Страница 18: ...Xenus Plus User Guide 16 01344 Rev 06 Copley Controls 18...
Страница 82: ...Xenus Plus User Guide 16 01344 Rev 06 Copley Controls 82 3 25 3 XE2 XP2 XM2 non N models 800 1819 Dimensions...
Страница 116: ...Xenus Plus User Guide 16 01344 Rev 06 Copley Controls 116 Optically Isolated Programmable Outputs Wiring Diagram...
Страница 120: ...Xenus Plus User Guide 16 01344 Rev 06 Copley Controls 120 Analog Input Wiring Diagram Multi Mode Port Interface Diagram...