Xenus Plus User Guide
16-01344 Rev 06
Copley Controls
114
4.11.2: Isolated Control - XEL/XPL/XML (J9)
Mating Connector
Description
Manufacturer PN
Wire Size
15 Position, High-density, D-Sub, male, solder cup.
Norcomp: 180-015-
103L001
24 - 30 AWG
Backshell
Norcomp: 979-009-
020R121
Solder style connector included in Connector Kits XEL-CK, XML-CK, and XPL-CK.
Pin connections for the bulkhead connector on the drive are shown here:
J9 Pin Description
Pin
Signal
Function
1
Frame Ground
Cable shield connection.
2
COMM_A
Common signal for first group of optically isolated programmable inputs.
3
IN7 GPI
Optically isolated programmable input.
4
IN8 GPI
5
IN9 GPI
6
IN10 GPI
7
COMM_B
Common signal for second group of optically isolated programmable inputs.
8
IN11 GPI
Optically isolated programmable input.
9
IN12 GPI
10
IN13 GPI
11
IN14 GPI
12
OUT5+ GPI
Optically isolated programmable output positive signal.
13
OUT5- GPI
Optically isolated programmable output negative signal.
14
OUT4+ GPI
Optically isolated programmable output positive signal.
15
OUT4- GPI
Optically isolated programmable output negative signal.
1
5
11
15
10
6
Содержание XEL-230-18
Страница 1: ...123123 P N 16 01344 Revision 06 August 30 2019 Xenus Plus User Guide...
Страница 2: ...Xenus Plus User Guide 16 01344 Rev 06 This page for notes...
Страница 9: ...Xenus Plus User Guide 16 01344 Rev 06 Copley Controls 9 This page for notes...
Страница 18: ...Xenus Plus User Guide 16 01344 Rev 06 Copley Controls 18...
Страница 82: ...Xenus Plus User Guide 16 01344 Rev 06 Copley Controls 82 3 25 3 XE2 XP2 XM2 non N models 800 1819 Dimensions...
Страница 116: ...Xenus Plus User Guide 16 01344 Rev 06 Copley Controls 116 Optically Isolated Programmable Outputs Wiring Diagram...
Страница 120: ...Xenus Plus User Guide 16 01344 Rev 06 Copley Controls 120 Analog Input Wiring Diagram Multi Mode Port Interface Diagram...