Xenus Plus User Guide
16-01344 Rev 06
Copley Controls
166
F.7: Copley Standard Regen Resistor Specifications
F.7.1: Specifications
Specifications for Copley’s standard regen resistors are described below.
Model
Resistance
Default
Continuous
Power
Max
Continuous
Power
Peak
Power
Peak
Power
Time
For Use With
XTL-RA-03
30 Ohms
65 W
400 W
5 kW
1000 ms
XEL/XML/XPL-230-18
XEL/XML/XPL-230-18-R
XTL-RA-04
15 Ohms
65 W
400 W
10 kW
1000 ms
XEL/XML/XPL-230-36
XEL/XML/XPL-230-36-R
XEL/XML/XPL-230-40t
XEL/XML/XPL-230-40-R
XE2/XP2/XM2-230-20
800-1818/800-1819/800-
1887
XE2/XP2/XM2-230-20-R
WARNING
High Temperature Risk.
Setting Default Continuous Power for a standard Copley regen resistor to a value greater
than the default of 65 W may cause the resistor casing to heat to temperatures that could
cause injury. If higher settings are required, contact Copley Controls customer support.
Failure to heed this warning can cause equipment damage or injury.
F.7.2: Dimensions
The diagram below shows XTL-RA-03 and XTL-RA-04 mounting dimensions (in mm).
!
Содержание XEL-230-18
Страница 1: ...123123 P N 16 01344 Revision 06 August 30 2019 Xenus Plus User Guide...
Страница 2: ...Xenus Plus User Guide 16 01344 Rev 06 This page for notes...
Страница 9: ...Xenus Plus User Guide 16 01344 Rev 06 Copley Controls 9 This page for notes...
Страница 18: ...Xenus Plus User Guide 16 01344 Rev 06 Copley Controls 18...
Страница 82: ...Xenus Plus User Guide 16 01344 Rev 06 Copley Controls 82 3 25 3 XE2 XP2 XM2 non N models 800 1819 Dimensions...
Страница 116: ...Xenus Plus User Guide 16 01344 Rev 06 Copley Controls 116 Optically Isolated Programmable Outputs Wiring Diagram...
Страница 120: ...Xenus Plus User Guide 16 01344 Rev 06 Copley Controls 120 Analog Input Wiring Diagram Multi Mode Port Interface Diagram...